SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING
DETAIL “A” |
|
Models 3600 and 3600XL | Model 3650 |
Burp Fitting
Burp Fitting
NOTE: Model 3650 shown. Models 3600 and 3600XL have the same contents in the disinfecting cabinet.
Disinfectant Valve
Injector
Screw
DETAIL
“C”
Disinfectant Cabinet Door
DETAIL “B”
| Knob | |
Floating | Flow | |
Meter | ||
Ball | ||
|
Disinfectant Siphon Tube
FIGURE 4.1 Calibrating the Disinfectant Flow Meter
Troubleshooting
SYMPTOMS | FAULTS | SOLUTION |
Hydromassage System |
|
|
|
|
|
System will not start. | No electrical power to tub. | Check and reset breaker. |
|
|
|
| System not prepared. | Be sure water level is ABOVE jets. |
|
|
|
|
| Check that inlet plug on tub is depressed. |
|
|
|
| Switch hose disconnected | Reconnect hose to switch and motor. |
|
|
|
System is ineffective. | Water deposits in whirlpool jets. | Disassemble and clean whirlpool jets. |
|
|
|
| Whirlpool jets closed. | Open whirlpool jets. |
|
|
|
| Aerator closed. | Open aerator. |
|
|
|
| Whirlpool intake clogged. | Inspect intake and remove obstruction. |
|
|
|
Tub Operation |
|
|
|
|
|
No water flow. | Water supply turned off. | Turn on water supply. |
|
|
|
Restricted water flow. | RADA valve. Refer to RADA | Inspect and clean RADA valve. |
| owner’s manual |
|
|
|
|
NOTE: If problems are not remedied by the suggested means above, contact an ICCG dealer or technical support.
Part No 1118387 | 33 | Side Entry Whirlpool Tub |