ResMed Mirage Micro manual Limited Warranty, Technical Specifications, Storage, Disposal

Page 9

Limited Warranty

ResMed warrants that your ResMed mask system, including its components: mask frame, cushion, headgear, tubing and other accessories (“Product”) shall be free from defects in material and workmanship for a period of ninety (90) days from the date of purchase by the initial consumer.

For further details refer to the Warranty.

Technical Specifications

Note: The mask system does not contain latex, PVC or DEHP materials.

Pressure–FlowThe mask contains passive venting to protect

Curveagainst rebreathing. As a result of manufacturing variations, the vent flow rate may vary.

 

50

 

 

 

 

 

 

 

Pressure

Flow

 

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(cm H2O)

(L/min)

(L/min)

40

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

4

19

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

Rate

 

 

 

 

 

 

 

8

28

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow

20

 

 

 

 

 

 

 

12

34

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent

10

 

 

 

 

 

 

 

16

40

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

20

45

 

4

6

8

10

12

14

16

18

20

 

 

 

 

Mask Pressure (cm H2O)

 

 

 

Dead Space

The dead space of the mask varies according to cushion size. It is

Information

128 mL for the Extra Large size.

 

 

Therapy Pressure

4 to 20 cm H2O

Resistance

Drop in pressure measured (nominal)

 

at 50 L/min: 0.1 cm H2O

 

at 100 L/min: 0.7 cm H2O

Environmental Operating temperature: +41°F to 104°F (+5°C to +40°C)

Conditions Operating humidity: up to 95% non-condensing

Storage and transport temperature: -4°F to 140°F (-20°C to +60°C)

Storage and transport humidity: up to 95% non-condensing

Gross

S:

140 mm (H) x 91 mm (W) x 93 mm (D)

dimensions

M, L, LW, XL: 155 mm (H) x 91 mm (W) x 98 mm (D)

 

Mask fully assembled – no headgear.

Note: The manufacturer reserves the right to change these specifications without notice.

Storage

Ensure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a cool dry place out of direct sunlight.

Disposal

The Mirage Micro does not contain any hazardous substances and may be disposed of with your normal household refuse.

8

Image 9
Contents Mirage Micro Intended Use Before Using the Mask16378 M* 16379 L* 16380 LW* 16381 XL Fitting the Mask Disassembling the Mask Reprocessing the Mask between Patients Cleaning the Mask at HomeReassembling the Mask Symbols TroubleshootingTechnical Specifications Limited WarrantyStorage DisposalVelcro is a registered trademark of Velcro Industries B.V AMER Multi