8 ASSEMBLING AND APPLYING THE CUFF

Fig. 8-1

Fig. 8-2

Fig. 8-3

Fig. 8-4

1.Unwrap the arm cuff, leaving the index end of the cuff through the D-ring of the cuff, as shown in

Fig. 8-1 above.

2.Ensure any clothing which restricts the upper left arm has been removed. Wrap the cuff around the upper arm. The tubing should point in the direction of the palm of the hand as shown in Fig. 8-6 below. Position the artery mark over the main artery (on the inside of the arm) of the upper arm. Wrap the cuff around the upper left arm using the end of the cuff so that the lower edge of the cuff is approximately 0.8-1.2 inches from the inner side of the elbow joint as shown in Fig. 8-3 above.

3.The right upper arm may be used instead of the left upper arm; however, it is necessary to know that the readings may differ 5 ~ 10 mmHg between left arm and right arm.

4.Press the cuff to make sure that it is attached securely as shown in Fig. 8-4 above. The cuff should not be too tight or too loose. Two fingers should be easily inserted between cuff and upper arm.

5.If the Index marker points into the Normal range (9"-14" arm circumference) indicated at the edge of the cuff, the cuff is suitable for use. If the Index line falls out of the Normal range, a different size cuff may be required. Call 1-800-672-8293 for more information regarding additional cuffs.

Fig. 8-5

Fig. 8-6

Fig. 8-7

10

Image 10
Contents Upper ARM SEMI-AUTOMATIC Digital Blood Pressure Monitor Contents Introduction Safety Symbols Parts and ComponentsPrinciple of Operation Tips on Taking Blood Pressure Measurement Battery Installation Setting the Date and Time Correct Posture for Measurement Assembling and Applying the Cuff Taking a Measurement 2 FigRapid Deflation During Measurement Memory Function Memory Recall Deleting the Memory Error and LOW Battery Information Indication Possible Reason Correction MethodsCARE, STORAGE, Repair and Recycling Troubleshooting Symptom Check Point RemedySpecifications TWO-YEAR Limited Warranty Blood Pressure Record LOG Pulse Beats/minute Date Page INS-LAB-RevB10 Contenidos Introducción Seguridad Piezas y componentes SímbolosGeneral Uso previsto Principio de OperaciónConsejos Para Tomar Mediciones DE LA Presión Arterial Instalación DE LAS Baterías Ajuste DE LA Fecha Y Hora Postura Correcta Para Medición EL Ensamblaje Y LA Aplicación DEL Manguito Tomando Medidas Deflación rápida durante la medición Función DE Memoria Memoria Borrando la memoria Información DE Errores Y Batería Baja Indicación Posible Causa Métodos DE CorreciónCUIDADO, ALMACENAMIENTO, Reparación Y Reciclaje Precaución No lave la vejiga interior del manguitoSolución DE Problemas Síntoma Check Point RecursoEspecificaciones ModeloGarantía Limitada DE DOS Años Fecha Fecha Sistólica MmHg Diastólica Pulso Latidos / minuto

1103 specifications

The Lumiscope 1103 is an innovative digital thermometer designed to provide quick and accurate temperature readings for both professional and personal use. This thermometer incorporates advanced technology that ensures reliability and ease of use, making it a popular choice among healthcare professionals and families alike.

One of the main features of the Lumiscope 1103 is its fast response time. Designed to deliver results in just a matter of seconds, the thermometer eliminates the long wait typically associated with traditional thermometers. Users can achieve accurate readings in approximately 60 seconds when measuring oral temperatures, making it an efficient tool for monitoring health.

Accuracy is paramount in any thermometer, and the Lumiscope 1103 does not disappoint. Equipped with a high-precision thermosensor, this device ensures that temperature readings are reliable and consistent, helping users to make informed health decisions. The thermometer can measure temperatures ranging from 89.6°F to 109.9°F (32°C to 43.3°C), accommodating a wide range of body temperatures.

Another notable characteristic of the Lumiscope 1103 is its user-friendly design. The digital display is large and easy to read, allowing users to quickly glance at their results without straining their eyes. The thermometer also features a beeping alarm that indicates when the reading is complete, ensuring users can be alerted without needing to watch the timer constantly.

The Lumiscope 1103 is not just quick and accurate; it is also designed for convenience and hygiene. The thermometer’s flexible tip enhances comfort during use, making it suitable for all ages, including infants. Additionally, the device is waterproof, allowing for easy cleaning and sanitization after each use.

For added convenience, the Lumiscope 1103 includes an automatic shut-off feature that helps to conserve battery life. This intelligent design choice means users don’t have to worry about the thermometer accidentally remaining powered on, resulting in prolonged operational life.

Overall, the Lumiscope 1103 is a reliable, efficient, and user-friendly digital thermometer that stands out for its accuracy, speed, and hygienic features. Whether for home use or in a clinical setting, this thermometer is an essential tool for effective health monitoring, ensuring users can keep track of their body temperature with confidence.