Lumiscope 1103 instruction manual Taking a Measurement, 2 Fig

Page 11

9 TAKING A MEASUREMENT

Note: Before taking a measurement, take 3 ~ 5 deep breaths and relax. In order to obtain accurate measurement results, remain seated, keep your arm and hands still, and do not talk during measurement.

Fig. 9-1 Fig. 9-2 Fig. 9-3

1.Insert the tube plug into the air connector on the side of the main body of the device.

2.Press button “O/”; all symbols will display for 2 seconds as shown in Fig. 9-1; you will hear two short beeps; then “0” will display with an upward arrow flashing as shown in Fig. 9-2, prompting the user to pump the inflation bulb to inflate the cuff.

If the cuff is already inflated, a downward arrow will display as shown in Fig. 9-3. In this case, press the rapid deflation valve to deflate the cuff before proceeding.

After excess air has been deflated from the cuff with the rapid deflation valve, “0” will display with an upward arrow flashing as shown in Fig. 9-2, prompting the user to inflate the cuff using the inflation bulb.

3.If you know the user’s typical systolic pressure, pump the inflation valve until a value of

~ 40 mmHg higher than the typical systolic pressure measurement is reached. If you do not

know the user’s typical systolic pressure, initially inflate the unit to 180 mmHg. If the pressure is

11

Image 11
Contents Upper ARM SEMI-AUTOMATIC Digital Blood Pressure Monitor Contents Introduction Safety Parts and Components SymbolsPrinciple of Operation Tips on Taking Blood Pressure Measurement Battery Installation Setting the Date and Time Correct Posture for Measurement Assembling and Applying the Cuff 2 Fig Taking a MeasurementRapid Deflation During Measurement Memory Function Memory Recall Deleting the Memory Indication Possible Reason Correction Methods Error and LOW Battery InformationCARE, STORAGE, Repair and Recycling Symptom Check Point Remedy TroubleshootingSpecifications TWO-YEAR Limited Warranty Blood Pressure Record LOG Pulse Beats/minute Date Page INS-LAB-RevB10 Contenidos Introducción Seguridad Símbolos Piezas y componentesPrincipio de Operación General Uso previstoConsejos Para Tomar Mediciones DE LA Presión Arterial Instalación DE LAS Baterías Ajuste DE LA Fecha Y Hora Postura Correcta Para Medición EL Ensamblaje Y LA Aplicación DEL Manguito Tomando Medidas Deflación rápida durante la medición Función DE Memoria Memoria Borrando la memoria Indicación Posible Causa Métodos DE Correción Información DE Errores Y Batería BajaPrecaución No lave la vejiga interior del manguito CUIDADO, ALMACENAMIENTO, Reparación Y ReciclajeSíntoma Check Point Recurso Solución DE ProblemasModelo EspecificacionesGarantía Limitada DE DOS Años Fecha Fecha Sistólica MmHg Diastólica Pulso Latidos / minuto

1103 specifications

The Lumiscope 1103 is an innovative digital thermometer designed to provide quick and accurate temperature readings for both professional and personal use. This thermometer incorporates advanced technology that ensures reliability and ease of use, making it a popular choice among healthcare professionals and families alike.

One of the main features of the Lumiscope 1103 is its fast response time. Designed to deliver results in just a matter of seconds, the thermometer eliminates the long wait typically associated with traditional thermometers. Users can achieve accurate readings in approximately 60 seconds when measuring oral temperatures, making it an efficient tool for monitoring health.

Accuracy is paramount in any thermometer, and the Lumiscope 1103 does not disappoint. Equipped with a high-precision thermosensor, this device ensures that temperature readings are reliable and consistent, helping users to make informed health decisions. The thermometer can measure temperatures ranging from 89.6°F to 109.9°F (32°C to 43.3°C), accommodating a wide range of body temperatures.

Another notable characteristic of the Lumiscope 1103 is its user-friendly design. The digital display is large and easy to read, allowing users to quickly glance at their results without straining their eyes. The thermometer also features a beeping alarm that indicates when the reading is complete, ensuring users can be alerted without needing to watch the timer constantly.

The Lumiscope 1103 is not just quick and accurate; it is also designed for convenience and hygiene. The thermometer’s flexible tip enhances comfort during use, making it suitable for all ages, including infants. Additionally, the device is waterproof, allowing for easy cleaning and sanitization after each use.

For added convenience, the Lumiscope 1103 includes an automatic shut-off feature that helps to conserve battery life. This intelligent design choice means users don’t have to worry about the thermometer accidentally remaining powered on, resulting in prolonged operational life.

Overall, the Lumiscope 1103 is a reliable, efficient, and user-friendly digital thermometer that stands out for its accuracy, speed, and hygienic features. Whether for home use or in a clinical setting, this thermometer is an essential tool for effective health monitoring, ensuring users can keep track of their body temperature with confidence.