Lumiscope 1103 instruction manual Correct Posture for Measurement

Page 9

7 CORRECT POSTURE FOR MEASUREMENT

Fig. 7-1

1.Sit down and place your left elbow on a table so that the upper arm cuff, when applied, will be at the same level as your heart.

Note: The level of your heart is slightly below your armpit;

2.Extend the left arm, palm up. Loosen and roll up left sleeve so that the blood pressure monitor cuff will be in direct contact with the left arm during measurement.

3.Relax your entire body, especially the area between your elbow and fingers.

4.If the cuff is not at the same level as the heart, or if you cannot keep your arm completely still throughout the measurement, use a soft object such as a folded towel to support your arm. Apply the cuff to the left arm as explained in the instructions on the following page.

9

Image 9
Contents Upper ARM SEMI-AUTOMATIC Digital Blood Pressure Monitor Contents Introduction Safety Parts and Components SymbolsPrinciple of Operation Tips on Taking Blood Pressure Measurement Battery Installation Setting the Date and Time Correct Posture for Measurement Assembling and Applying the Cuff 2 Fig Taking a MeasurementRapid Deflation During Measurement Memory Function Memory Recall Deleting the Memory Indication Possible Reason Correction Methods Error and LOW Battery InformationCARE, STORAGE, Repair and Recycling Symptom Check Point Remedy TroubleshootingSpecifications TWO-YEAR Limited Warranty Blood Pressure Record LOG Pulse Beats/minute Date Page INS-LAB-RevB10 Contenidos Introducción Seguridad Símbolos Piezas y componentesPrincipio de Operación General Uso previstoConsejos Para Tomar Mediciones DE LA Presión Arterial Instalación DE LAS Baterías Ajuste DE LA Fecha Y Hora Postura Correcta Para Medición EL Ensamblaje Y LA Aplicación DEL Manguito Tomando Medidas Deflación rápida durante la medición Función DE Memoria Memoria Borrando la memoria Indicación Posible Causa Métodos DE Correción Información DE Errores Y Batería BajaPrecaución No lave la vejiga interior del manguito CUIDADO, ALMACENAMIENTO, Reparación Y ReciclajeSíntoma Check Point Recurso Solución DE ProblemasModelo EspecificacionesGarantía Limitada DE DOS Años Fecha Fecha Sistólica MmHg Diastólica Pulso Latidos / minuto

1103 specifications

The Lumiscope 1103 is an innovative digital thermometer designed to provide quick and accurate temperature readings for both professional and personal use. This thermometer incorporates advanced technology that ensures reliability and ease of use, making it a popular choice among healthcare professionals and families alike.

One of the main features of the Lumiscope 1103 is its fast response time. Designed to deliver results in just a matter of seconds, the thermometer eliminates the long wait typically associated with traditional thermometers. Users can achieve accurate readings in approximately 60 seconds when measuring oral temperatures, making it an efficient tool for monitoring health.

Accuracy is paramount in any thermometer, and the Lumiscope 1103 does not disappoint. Equipped with a high-precision thermosensor, this device ensures that temperature readings are reliable and consistent, helping users to make informed health decisions. The thermometer can measure temperatures ranging from 89.6°F to 109.9°F (32°C to 43.3°C), accommodating a wide range of body temperatures.

Another notable characteristic of the Lumiscope 1103 is its user-friendly design. The digital display is large and easy to read, allowing users to quickly glance at their results without straining their eyes. The thermometer also features a beeping alarm that indicates when the reading is complete, ensuring users can be alerted without needing to watch the timer constantly.

The Lumiscope 1103 is not just quick and accurate; it is also designed for convenience and hygiene. The thermometer’s flexible tip enhances comfort during use, making it suitable for all ages, including infants. Additionally, the device is waterproof, allowing for easy cleaning and sanitization after each use.

For added convenience, the Lumiscope 1103 includes an automatic shut-off feature that helps to conserve battery life. This intelligent design choice means users don’t have to worry about the thermometer accidentally remaining powered on, resulting in prolonged operational life.

Overall, the Lumiscope 1103 is a reliable, efficient, and user-friendly digital thermometer that stands out for its accuracy, speed, and hygienic features. Whether for home use or in a clinical setting, this thermometer is an essential tool for effective health monitoring, ensuring users can keep track of their body temperature with confidence.