Systolic Blood |
|
Pressure Display |
|
| MEMORY |
Diastolic Blood | RECALL button |
Pressure Display | Push this button to |
| see the measured |
Date/Time Display | values stored in | |
the monitor. | ||
|
Please disconnect your 637IT from your PC when you replace the batteries.
With new batteries (long life alkaline batteries) you are able to measure app. 300 times under normal conditions. Please switch of the monitor after using it. If you forget to switch the monitor off it will switch off itself after app. 2 minutes. Please take the batteries out of the monitor if you intend not to use the monitor for a long period (app. 2 months).
How to Set the Date and Time
English
| GRAPH CALL | Before using your OMRON 637IT for the first time, you have to | |
Mark | button | ||
set the date and time. After turning the monitor on by pushing the | |||
Displayed when a stored | Push this button to | ||
O/I button the initial screen (see picture) will be available for a | |||
measurement is shown. | see the graph. | ||
few seconds. After the initial screen you will proceed automatical- | |||
|
|
Pulse Display
button
Push to move the displayed item forward. Push to move the dis- played item backward.
SETTING button
Push this button to set various items on the moni- tor such as time and date.
ON/OFF button
Push this button to measure your blood pressure or to switch the moni- tor off.
ly to the TIME SET screen. (For instruction how to set the date and time refer also to page 16 in Chapter How to change the set- tings.)
After reaching the time screen you will see the Gregorian calen- dar (year day/month). The year will be flashing.
1. By using the ( | ) buttons you can set the current year. |
2.By pushing the SET button you will lock the year and proceed to the next item.
For setting the month, date and time repeat step 1 and 2. After
Initial Screen
How to Insert the Batteries
Use this monitor after inserting batteries in the main unit.
setting the minutes you will proceed to the DELETE DATA screen. Please turn off your monitor by pushing the O/I button. Your OMRON 637IT is ready for use now.
Time Screen
1. Open the battery compartment.
2. Insert the batteries (Type LR03 / AAA) as shown in the figure.
Ensure the polarity
How to Measure Blood Pressure Correctly
How to wrap the cuff
In order to measure your blood pressure correctly it is needed to wrap the cuff around your wrist in a correct way. If not, correct measurements are not possible. Please follow the coming instructions (left wrist):
1)Make sure that your wrist is bare and will be wrapped over your skin.
2)Make sure that you clothing is not constraining the flow of your blood.
3)Make sure that the wrist (left or right) to measure is selected from the settings menu (see also page 15). The left wrist is preset.
3. Close the battery cover.
6 | 7 |