Panasonic CU-XE9PKUA, CS-XE12PKUA, CS-XE9PKUA, CU-XE12PKUA manual Table of Contents

Page 2

TABLE OF CONTENTS

1.

Safety Precautions

3

2.

Specifications

5

3.

Features

11

4.

Location of Controls and Components

12

4.1

Indoor Unit

12

4.2

Outdoor Unit

12

4.3

Remote Control

12

5.

Dimensions

13

5.1

Indoor Unit

13

5.2

Outdoor Unit

14

6.

Refrigeration Cycle Diagram

15

7.

Block Diagram

16

8.

Wiring Connection Diagram

17

8.1

Indoor Unit

17

8.2

Outdoor Unit

18

9.

Electronic Circuit Diagram

19

9.1

Indoor Unit

19

9.2

Outdoor Unit

20

10.

Printed Circuit Board

21

10.1

Indoor Unit

21

10.2

Outdoor Unit

23

11.

Installation Instruction

24

11.1

Select the Best Location

24

11.2

Indoor Unit

25

11.3

Outdoor Unit

29

12.

Operation Control

32

12.1

Basic Function

32

12.2

Indoor Fan Motor Operation

33

12.3

Outdoor Fan Motor Operation

34

12.4

Airflow Direction

35

12.5Quiet operation (Cooling Mode/Cooling area

 

of Dry Mode)

36

12.6

Quiet Operation (Heating)

36

12.7

Powerful Mode Operation

37

12.8

Timer Control

37

12.9

Auto Restart Control

37

12.10

Indication Panel

37

12.11 Room Freeze Protection Function (RFP)

 

 

Operation

38

12.12 AUTO COMFORT and ECONAVI

 

 

Operation

38

13. Protection Control

44

13.1

Protection Control For All Operations

44

13.2Protection Control For Cooling & Soft Dry

Operation

46

13.3Protection Control For Heating

 

Operation

47

14. Servicing Mode

48

14.1

Auto OFF/ON Button

48

14.2

Remote Control Button

49

15. Troubleshooting Guide

50

15.1

Refrigeration Cycle System

50

15.2

Breakdown Self Diagnosis Function

52

15.3

Error Codes Table

53

15.4

Self-diagnosis Method

55

16. Disassembly and Assembly Instructions

82

16.1

Indoor Electronic Controllers, Cross Flow Fan

 

and Indoor Fan Motor Removal

 

 

Procedures

82

16.2

Outdoor Electronic Controller Removal

 

 

Procedure

87

17. Technical Data

88

17.1

Operation Characteristics

88

17.2

Sensible Capacity Chart

96

18. Exploded View and Replacement Parts

 

List

.....................................................................

97

18.1

Indoor Unit

97

18.2

Outdoor Unit

100

2

Image 2
Contents Air Conditioner CU-XE12PKUATable of Contents Safety Precautions š The items to be followed are classified by the symbolsPage Specifications CU-XE9PKUASeer / Hspf CS-XE9PKUA CU-XE9PKUA CS-XE12PKUA CU-XE12PKUA CS-XE12PKUA Pipe Diameter Liquid / Gas Mm inch Features š Inverter TechnologyIndoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Model CU-XE9/12PK Connection Electronic Circuit Diagram Outdoor Unit Main Printed Circuit Board Indicator Printed Circuit Board Printed Circuit BoardPage Main Printed Circuit Board Select the Best Location Installation InstructionIndoor/Outdoor Unit Installation Diagram Indoor UnitTo Drill a Hole in the Wall and Install a Sleeve of Piping Indoor Unit Installation Page Connect the Cable to the Indoor Unit Install the Outdoor Unit Connect the PipingEvacuation of the Equipment Connect the Cable to the Outdoor UnitPiping Insulation Cutting and flaring the pipingOperation Control Basic FunctionFan Operation Indoor Fan Motor OperationAutomatic Operation Basic Rotation Speed rpmOutdoor Fan Motor Operation Feedback controlAirflow Direction Vertical AirflowHorizontal Airflow Quiet operation Cooling Mode/Cooling area of Dry ModeQuiet Operation Heating Auto Restart Control Powerful Mode OperationTimer Control Indication PanelRoom Freeze Protection Function RFP Operation Auto Comfort and Econavi OperationHuman Activity Sensor Information Log Rhythmic Temperature Wave Operation Econavi and Auto Comfort Demo Mode Human Activity Sensor Check Mode Protection Control Restart Control Time Delay Safety ControlIPM Power transistor Prevention Control Protection Control For All OperationsLow Frequency Protection Control Compressor Overheating Prevention ControlLow Pressure Prevention Control Gas Leakage Detection Cooling Overload Control Outdoor Air Temperature ControlProtection Control For Cooling & Soft Dry Operation Freeze Prevention ControlProtection Control For Heating Operation Servicing Mode Auto OFF/ON ButtonReset AC Remote Control ButtonReset RC TimerTroubleshooting Guide Refrigeration Cycle SystemCondition Cooling Mode Heating Mode Self Diagnosis Function Three Digits Alphanumeric Code To Display Memorized Error Code Protective OperationBreakdown Self Diagnosis Function To Make a DiagnosisError Codes Table Protection controlDiagnosis Abnormality Protection Problem Self-diagnosis Method 15.4.1 H11 Indoor/Outdoor Abnormal Communication15.4.2 H12 Indoor/Outdoor Capacity Rank Mismatched 15.4.3 H14 Indoor Intake Air Temperature Sensor Abnormality 15.4.4 H15 Compressor Temperature Sensor Abnormality 15.4.5 H16 Outdoor Current Transformer 15.4.6 H19 Indoor Fan Motor DC Motor Mechanism Locked 15.4.7 H23 / H24 Indoor Pipe Temperature Sensor Abnormality 15.4.8 H27 Outdoor Air Temperature Sensor Abnormality 15.4.9 H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions Malfunction Decision Conditions 15.4.12 H33 Unspecified Voltage between Indoor and Outdoor 15.4.13 H36 Outdoor Gas Pipe Sensor Abnormality Malfunction Decision Conditions 15.4.15 H97 Outdoor Fan Motor DC Motor Mechanism Locked Malfunction Decision Conditions Malfunction Caused 15.4.18 F11 4-way Valve Switching Failure 15.4.19 F17 Indoor Standby Units Freezing Abnormality Remark15.4.20 F90 Power Factor Correction Protection 15.4.21 F91 Refrigeration Cycle Abnormality 15.4.22 F93 Compressor Rotation Failure Malfunction Decision Conditions 15.4.24 F96 IPM Overheating Multi Models only15.4.25 F97 Compressor Overheating 15.4.26 F98 Input Over Current Detection 15.4.27 F99 DC Peak Detection Disassembly and Assembly Instructions To remove front grille To remove electronic controllerTo remove discharge grille Page Page Page Outdoor Electronic Controller Removal Procedure Technical Data Operation CharacteristicsPage Page Page CS-XE12PKUA CU-XE12PKUA Page Page Page Sensible Capacity Chart š CU-XE9PKUAExploded View and Replacement Parts List CS-XE9PKUA CS-XE12PKUARemark BAG Outdoor Unit 101 Shock Absorber Right

CU-XE12PKUA, CU-XE9PKUA, CS-XE9PKUA, CS-XE12PKUA specifications

The Panasonic CU-XE9PKUA, CU-XE12PKUA, CS-XE12PKUA, and CS-XE9PKUA are part of Panasonic's advanced lineup of air conditioning units, designed to deliver reliable comfort and energy efficiency in residential and commercial settings. These models are engineered with cutting-edge technology to ensure optimal performance, sustainability, and user convenience.

One of the standout features of these air conditioning units is their high energy efficiency ratings. Equipped with inverter technology, they adjust the compressor’s speed according to the temperature, maintaining the desired comfort level without unnecessary energy consumption. This not only reduces electricity bills but also ensures a smaller carbon footprint, making them an eco-friendly choice.

The CU-XE9PKUA and CU-XE12PKUA units are outdoor models, which seamlessly pair with their indoor counterparts, the CS-XE9PKUA and CS-XE12PKUA, respectively. This split system design provides versatile installation options while ensuring quiet operation. The outdoor units are built to withstand a variety of weather conditions, contributing to their durability and longevity.

In addition to their robust energy efficiency, these units feature advanced cooling and heating capabilities. With the inclusion of Panasonic’s unique “nanoe-G” technology, these models not only cool or heat the air but also purify it. Nanoe-G technology releases hydroxyl radicals that effectively eliminate harmful particles, such as bacteria and allergens, ensuring that the air you breathe is cleaner and healthier.

The design of the indoor units is sleek and modern, integrating easily into any décor. With features like quiet operation, they are perfect for bedrooms and quiet spaces, ensuring that the comfort of climate control does not come at the expense of serenity.

User convenience is further enhanced with smart control options. Many of the models come equipped with Wi-Fi connectivity, allowing users to control their air conditioning systems remotely via a smartphone app. This means adjusting temperature settings, scheduling operations, or activating modes can be done effortlessly, ensuring maximum comfort at all times.

Overall, Panasonic's CU-XE9PKUA, CU-XE12PKUA, CS-XE12PKUA, and CS-XE9PKUA models combine innovative technology, energy efficiency, and user-friendly features, making them excellent choices for anyone seeking reliable climate control solutions. Whether for residential use or commercial applications, these air conditioners promise to deliver comfort, quality, and peace of mind.