Panasonic CU-XE9PKUA, CS-XE12PKUA, CS-XE9PKUA, CU-XE12PKUA manual Remark

Page 98

SAFETY

REF. NO.

PART NAME & DESCRIPTION

QTY.

CS-XE9PKUA

 

 

 

 

 

 

1

CHASSIS COMPLETE

1

CWD50C1730

 

 

 

 

 

 

2

FAN MOTOR

1

ARW7715AC

 

 

 

 

 

 

3

CROSS - FLOW FAN COMPLETE

1

CWH02C1137

 

 

 

 

 

 

4

BEARING ASSY

1

CWH64K1010

 

 

 

 

 

 

4a

SCREW – CROSS - FLOW FAN

1

CWH551146

 

 

 

 

 

 

6

EVAPORATOR

1

CWB30C4585

 

 

 

 

 

 

7

FLARE NUT (LIQUID)

1

CWT251030

 

 

 

 

 

 

8

FLARE NUT (GAS)

1

CWT251031

 

 

 

 

 

 

9

CLIP FOR SENSOR

2

CWH711019

 

 

 

 

 

 

10

BACK COVER CHASSIS

1

CWD933463

 

 

 

 

 

 

11

DISCHARGE GRILLE COMPLETE

1

CWE20C3419

 

 

 

 

 

 

12

VERTICAL VANE

8

CWE241389

 

 

 

 

 

 

13

VERTICAL VANE

2

CWE241409

 

 

 

 

 

 

14

CONNECTING BAR

2

CWE261272

 

 

 

 

 

 

17

LEAD WIRE - COMPLETE

1

CWA68C0784

 

 

 

 

 

 

17a

LEAD WIRE - COMPLETE

1

CWA68C0786

 

 

 

 

 

 

18

FULCRUM

1

CWH621157

 

 

 

 

 

 

19

HORIZONTAL VANE COMPLETE

1

CWE24C1422

 

 

 

 

 

 

20

HORIZONTAL VANE COMPLETE

1

CWE24C1421

 

 

 

 

 

 

21

AIR SWING MOTOR

1

CWA981241

 

 

 

 

 

 

22

AIR SWING MOTOR

1

CWA981299

 

 

 

 

 

 

23

CAP - DRAIN TRAY

1

CWH521259

 

 

 

 

 

 

24

SENSOR COMPLETE

1

CWA50C2800

 

 

 

 

 

 

25

ELECTRONIC CONTROLLER - MAIN

1

CWA73C7809

 

 

 

 

 

 

27

CONTROL BOARD CASING

1

CWH102564A

 

 

 

 

 

 

28

CONTROL BOARD TOP COVER

1

CWH131531

 

 

 

 

 

 

29

CONTROL BOARD FRONT COVER CO.

1

CWH13C1309

 

 

 

 

 

 

30

TERMINAL BOARD COMPLETE

1

CWA28C2616

 

 

 

 

 

 

31

ELECTRONIC CONTROLLER - INDICATOR

1

CWA747457

 

 

 

 

 

 

31a

ELECTRONIC CONTROLLER - RECEIVER

1

CWA747456

 

 

 

 

 

 

32

INDICATOR HOLDER

1

CWD933466

 

 

 

 

 

 

33

FRONT GRILLE COMPLETE

1

CWE11C5689

 

 

 

 

 

 

34

GRILLE DOOR COMPLETE

1

CWE14C1099

 

 

 

 

 

 

35

INTAKE GRILLE COMPLETE

1

CWE22K1610

 

 

 

 

 

 

36

DECORATION BASE (LEFT)

1

CWE35K1166

 

 

 

 

 

 

37

DECORATION BASE (RIGHT)

1

CWE351326

 

 

 

 

 

 

38

SCREW - FRONT GRILLE

2

XTT4+16CFJ

 

 

 

 

 

 

39

AIR FILTER

2

CWD001326

 

 

 

 

 

 

40

DRAIN HOSE

1

CWH851173

 

 

 

 

 

 

41

REMOTE CONTROL COMPLETE

1

CWA75C4246

 

 

 

 

 

 

42

INSTALLATION PLATE

1

CWH361134

 

 

 

 

 

 

43

BAG COMPLETE - INSTALLATION SCREW

1

CWH82C1705

 

 

 

 

 

 

44

OPERATING INSTRUCTION

1

CWF569182

 

 

 

 

 

 

45

INSTALLATION INSTRUCTION

1

CWF615968

 

 

 

 

 

 

46

INSTALLATION INSTRUCTION

1

CWF615977

 

 

 

 

 

 

57

SENSOR COMPLETE (ECO)

1

CWA50C3005

 

 

 

 

 

 

58

AIR SWING MOTOR (ECO)

1

CWA981298

 

 

 

 

 

 

59

ELECTRONIC CONTROLLER

1

CWA746917

 

 

 

 

 

 

60

ELECTRONIC CONTROLLER

1

CWA747279

 

 

 

 

 

CS-XE12PKUA

CWB30C4588

CWT251032

CWA73C7810

REMARK

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

98

Image 98
Contents Air Conditioner CU-XE12PKUATable of Contents Safety Precautions š The items to be followed are classified by the symbolsPage Specifications CU-XE9PKUASeer / Hspf CS-XE9PKUA CU-XE9PKUA CS-XE12PKUA CU-XE12PKUA CS-XE12PKUA Pipe Diameter Liquid / Gas Mm inch Features š Inverter TechnologyIndoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Model CU-XE9/12PK Connection Electronic Circuit Diagram Outdoor Unit Main Printed Circuit Board Indicator Printed Circuit Board Printed Circuit BoardPage Main Printed Circuit Board Select the Best Location Installation InstructionIndoor/Outdoor Unit Installation Diagram Indoor UnitTo Drill a Hole in the Wall and Install a Sleeve of Piping Indoor Unit Installation Page Connect the Cable to the Indoor Unit Install the Outdoor Unit Connect the PipingEvacuation of the Equipment Connect the Cable to the Outdoor UnitPiping Insulation Cutting and flaring the pipingOperation Control Basic FunctionFan Operation Indoor Fan Motor OperationAutomatic Operation Basic Rotation Speed rpmOutdoor Fan Motor Operation Feedback controlAirflow Direction Vertical AirflowHorizontal Airflow Quiet operation Cooling Mode/Cooling area of Dry ModeQuiet Operation Heating Auto Restart Control Powerful Mode OperationTimer Control Indication PanelRoom Freeze Protection Function RFP Operation Auto Comfort and Econavi OperationHuman Activity Sensor Information Log Rhythmic Temperature Wave Operation Econavi and Auto Comfort Demo Mode Human Activity Sensor Check Mode Protection Control Restart Control Time Delay Safety ControlIPM Power transistor Prevention Control Protection Control For All OperationsLow Frequency Protection Control Compressor Overheating Prevention ControlLow Pressure Prevention Control Gas Leakage Detection Cooling Overload Control Outdoor Air Temperature ControlProtection Control For Cooling & Soft Dry Operation Freeze Prevention ControlProtection Control For Heating Operation Servicing Mode Auto OFF/ON ButtonReset AC Remote Control ButtonReset RC TimerTroubleshooting Guide Refrigeration Cycle SystemCondition Cooling Mode Heating Mode Self Diagnosis Function Three Digits Alphanumeric Code To Display Memorized Error Code Protective OperationBreakdown Self Diagnosis Function To Make a DiagnosisError Codes Table Protection controlDiagnosis Abnormality Protection Problem Self-diagnosis Method 15.4.1 H11 Indoor/Outdoor Abnormal Communication15.4.2 H12 Indoor/Outdoor Capacity Rank Mismatched 15.4.3 H14 Indoor Intake Air Temperature Sensor Abnormality 15.4.4 H15 Compressor Temperature Sensor Abnormality 15.4.5 H16 Outdoor Current Transformer 15.4.6 H19 Indoor Fan Motor DC Motor Mechanism Locked 15.4.7 H23 / H24 Indoor Pipe Temperature Sensor Abnormality 15.4.8 H27 Outdoor Air Temperature Sensor Abnormality 15.4.9 H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions Malfunction Decision Conditions 15.4.12 H33 Unspecified Voltage between Indoor and Outdoor 15.4.13 H36 Outdoor Gas Pipe Sensor Abnormality Malfunction Decision Conditions 15.4.15 H97 Outdoor Fan Motor DC Motor Mechanism Locked Malfunction Decision Conditions Malfunction Caused 15.4.18 F11 4-way Valve Switching Failure 15.4.19 F17 Indoor Standby Units Freezing Abnormality Remark15.4.20 F90 Power Factor Correction Protection 15.4.21 F91 Refrigeration Cycle Abnormality 15.4.22 F93 Compressor Rotation Failure Malfunction Decision Conditions 15.4.24 F96 IPM Overheating Multi Models only15.4.25 F97 Compressor Overheating 15.4.26 F98 Input Over Current Detection 15.4.27 F99 DC Peak Detection Disassembly and Assembly Instructions To remove front grille To remove electronic controllerTo remove discharge grille Page Page Page Outdoor Electronic Controller Removal Procedure Technical Data Operation CharacteristicsPage Page Page CS-XE12PKUA CU-XE12PKUA Page Page Page Sensible Capacity Chart š CU-XE9PKUAExploded View and Replacement Parts List CS-XE9PKUA CS-XE12PKUARemark BAG Outdoor Unit 101 Shock Absorber Right

CU-XE12PKUA, CU-XE9PKUA, CS-XE9PKUA, CS-XE12PKUA specifications

The Panasonic CU-XE9PKUA, CU-XE12PKUA, CS-XE12PKUA, and CS-XE9PKUA are part of Panasonic's advanced lineup of air conditioning units, designed to deliver reliable comfort and energy efficiency in residential and commercial settings. These models are engineered with cutting-edge technology to ensure optimal performance, sustainability, and user convenience.

One of the standout features of these air conditioning units is their high energy efficiency ratings. Equipped with inverter technology, they adjust the compressor’s speed according to the temperature, maintaining the desired comfort level without unnecessary energy consumption. This not only reduces electricity bills but also ensures a smaller carbon footprint, making them an eco-friendly choice.

The CU-XE9PKUA and CU-XE12PKUA units are outdoor models, which seamlessly pair with their indoor counterparts, the CS-XE9PKUA and CS-XE12PKUA, respectively. This split system design provides versatile installation options while ensuring quiet operation. The outdoor units are built to withstand a variety of weather conditions, contributing to their durability and longevity.

In addition to their robust energy efficiency, these units feature advanced cooling and heating capabilities. With the inclusion of Panasonic’s unique “nanoe-G” technology, these models not only cool or heat the air but also purify it. Nanoe-G technology releases hydroxyl radicals that effectively eliminate harmful particles, such as bacteria and allergens, ensuring that the air you breathe is cleaner and healthier.

The design of the indoor units is sleek and modern, integrating easily into any décor. With features like quiet operation, they are perfect for bedrooms and quiet spaces, ensuring that the comfort of climate control does not come at the expense of serenity.

User convenience is further enhanced with smart control options. Many of the models come equipped with Wi-Fi connectivity, allowing users to control their air conditioning systems remotely via a smartphone app. This means adjusting temperature settings, scheduling operations, or activating modes can be done effortlessly, ensuring maximum comfort at all times.

Overall, Panasonic's CU-XE9PKUA, CU-XE12PKUA, CS-XE12PKUA, and CS-XE9PKUA models combine innovative technology, energy efficiency, and user-friendly features, making them excellent choices for anyone seeking reliable climate control solutions. Whether for residential use or commercial applications, these air conditioners promise to deliver comfort, quality, and peace of mind.