Sunrise Medical F50 owner manual Procedures for Charging V 10A charger

Page 30

Batteries and charging

Procedures for Charging. 24V 10A charger

The 24V 10A charger has one bi-coloured orange/green indicator to show the charger operation (Fig. 29).

1Plug into the three pin charging point under the fornt of the control box (Fig. 28).

2Connect the charger to the mains supply by means of the mains plug and switch on.

3At the start of charging the charger will undergo a self test procedure, this is indicated by the indicator flashing, alternating orange/green (Fig. 29).

4When the test is complete and there have been no faults found, charging will commence. This is indicated by a flashing orange only light.

5On return of 90% or the bulk of the charge a steady orange light will be visible.

6When a steady green light is visible the battery is fully charged.

7An automatic switch to a float voltage will occur after a further period of time, and the charger should be left connected to the wheelchair until it is required for use.

8No light indicator will show unless the charging plugs are connected.

9Always switch off at the mains before disconnecting the batteries.

Control box

Charger socket

Fig. 28

Orange/green warning light

Fig. 29

On/Off switch on rear case

27

Issue 4

 

 

Image 30
Contents Page How to use this manual Page Introduction Serial NumberGuarantee Your guaranteeFeatures and options General Safety warningsRoutine service KerbsBatteries Cleaning seatingCleaning controls TyresWheelchair range Use on a slopeMobile telephones and two way radios Power-base assembly Preparing your wheelchair for useFitting the batteries Attaching the rear view mirrorThen re-tightening Fitting the seat frame Seat stem adjustment Seat pan height adjustment Removal of seat frameArmrests/skirt guard Attaching the backrest Fitting footrestsImmobiliser plug Power supplyPenny and Giles Pilot + control pod To activate the immobiliserAdjustable speed setting Battery level indicatorIndicators Horn buttonHazard lights Main lightsLegrest left Actuator mode functionMenu select Seat tiltCharging socket Operation the control joystickSummary Parallel Swing-Away Arm Mounting the kerb Using your wheelchairKerb climber Fitting Dismounting the kerbKerb climber Caution It is not intended for permanent useBatteries and charging Maintenance free batteriesBattery care General informationMaintenance free battery care plan Safety features Mains supply Fault finding guideNo indicator Deeply discharged batteriesProcedures for Charging V 10A charger Safety and caution notes Battery warranty Range of your vehicle Myths and legendsUser tips Adverse conditionsRamps Transfer to and from the chair Gradients ascents Gradients descentsTransportation Clamp pointsMaintenance Lap belt instructionsMaintenance F50 maintenance and routine inspection To order spare partsService history YearSunrise Medical Sunrise Medical LimitedIssue Sunrise Medical Limited