V I I . C A R E A N D M A I N T E N A N C E

„All wheel bearings are prelubricated and sealed. They require no subsequent lubrication.

„The body shroud has been sprayed with a clear sealant coating. You can apply a light coat of car wax to help it retain its high-gloss appearance.

„Check all electrical connections. Make sure they are tight and are not corroded. Batteries must sit flat within the battery well, with the battery terminals facing inward, toward each other. Refer to the frame decal for the correct wiring layout.

WARNING! Even though the power chair has passed the necessary testing requirements for ingress of liquids, you should keep electrical connections away from sources of dampness, including direct exposure to water or bodily fluids and incontinence. Check electrical components frequently for signs of corrosion and replace as necessary.

Daily Checks

„With the controller turned off, check the joystick. Make sure it is not bent or damaged and that it returns to the neutral position when you release it. Check the rubber boot around the base of the joystick for damage. Visually inspect the boot. Do not handle or try to repair it. See your Quantum Rehab Provider if there is a problem.

„Visually inspect the controller harness. Make sure that it is not frayed, cut, or has any wires exposed. See your Quantum Rehab Provider if there is a problem with any harnesses.

„Check for flat spots on solid tires. Flat spots could adversely affect stability.

„Inspect the armrests for loose hardware, stress points, or damage. See your Quantum Rehab Provider if there is a problem.

Weekly Checks

„Disconnect and inspect the controller from the electronics tray. Look for corrosion. Contact your Quantum Rehab Provider if necessary.

„Ensure that all parts of the controller system are securely fastened to your power chair. Do not overtighten any screws.

„Check for proper tire inflation. Maintain but do not exceed the psi/bar/kPa air pressure rating indicated on each tire for pneumatic tires. If a tire does not hold air, see your Quantum Rehab Provider for replacement of the tube.

„Check the brakes. This test should be carried out on a level surface with at least three feet (1 meter) of clearance around your power chair.

To check the brakes:

1.Turn on the controller and turn down the speed level of your power chair.

2.After one second, check the battery condition meter. Make sure that it remains on.

3.Slowly push the joystick forward until you hear the electric brakes click. Immediately release the joystick. You must be able to hear each electrical brake operating within a few seconds of joystick movement. Repeat this test three times, pushing the joystick backward, then left, and then right.

Monthly Checks

„Check that the anti-tip wheels do not rub the ground when you operate the power chair. Adjust them as necessary. See V. “Comfort Adjustments.”

„Check for extreme wear on the anti-tip wheels. Replace them as necessary.

„Check for drive tire wear. See a Quantum Rehab Provider for repair.

„Check the rear casters for wear. Replace them as necessary.

„Check the rear forks for damage or fluttering which indicates that they may need to be adjusted or have the bearings replaced. See a Quantum Rehab Provider for repair.

„Keep your power chair clean and free of foreign material, such as mud, dirt, hair, food, drink, etc.

Quantum 1121 Series

www.pridemobility.com

31

Image 31
Contents Quantum Quick Reference Information F E T Y G U I D E L I N E SIII N T E N T SShipping and Delivery SafetyN T R O D U C T I O N PURCHASER’S AgreementS a F E T Y Product Safety SymbolsS a F E T Y General Guidelines Pre-Ride Safety CheckModifications Tire Inflation Weight LimitationsIncline Information Braking Information Freewheel ModeCornering Information Public Streets and Roadways Outdoor Driving Surfaces Inclement Weather PrecautionsStationary Obstacles Steps, Curbs, etc Lift/Elevation Products Stairs and EscalatorsDoors ElevatorsBatteries Positioning BeltsPrescription Drugs/Physical Limitations TransfersElectromagnetic and Radio Frequency Interference EMI/RFI Alcohol/SmokingI . Y O U R P O W E R C H a I R Quantum 1121 Series Power ChairActive-Trac Suspension Electronics TrayTo operate the dual manual freewheel levers Manual Freewheel LeverSeat Installation Initial AssemblyA S S E M B L Y Controller Harness Routing Contour Seat To install the seatO M F O R T a D J U S T M E N T S Comfort AdjustmentsYou may need the following to make comfort adjustments Seat Height and Seat Angle AdjustmentManual Recline Seatback Adjustment Seat Position AdjustmentArmrest Angle Adjustment Seatback Angle AdjustmentArmrest Width Adjustment Armrest Height AdjustmentFoot Platform Depth Adjustment Foot Platform Height AdjustmentController Position Anti-Tip Wheels Foot Platform Angle AdjustmentTo adjust the foot platform angle To adjust the anti-tip wheelsTo change the seat height through toggle switch Power Elevating Seat OptionalTo use the swivel feature Batteries and Charging B a T T E R I E S a N D C H a R G I N GCharging the Batteries Frequently Asked Questions FAQs Battery Break-inHow can I get maximum range or distance per charge? Why do my new batteries seem weak?„ Daily Use „ Infrequent UseWhat about shipping? How can I ensure maximum battery life?How should I store my power chair and its batteries? What about public transportation?I . C a R E a N D M a I N T E N a N C E Care and MaintenanceShould your power chair come in contact with water TemperatureMonthly Checks Daily ChecksWeekly Checks To check the brakesYearly Checks Disposal of Your Power ChairCleaning Instructions Wheel ReplacementDrive Wheel Battery ReplacementTerminal. See figure When to See Your Quantum Rehab Provider for ServiceCorrective Maintenance To replace the batteriesSpecifications P E N D I X I Specification SQuantum 1121 Series Dimensions and Ground Clearance T E S T E S Product Serial # Quality Control Quantum 1121 Series