Pride Mobility JAZZY 1101, JAZZY 1121 Electronics Tray, Active-Trac Suspension 1121 Only

Page 18

I V . T H E J A Z Z Y 1 1 0 1 / 1 1 2 1

Electronics Tray

The electronics tray is located on the back of the power base. See figures 3 and 4. The ammeter, the onboard chargerAC power cord, the main circuit breaker, the controller connector, and the charger fuse are all located on the electronics tray.

Ammeter: The ammeter displays the charger’s current output in amps. See VII. “Batteries and Charging.”

Onboard Charger AC Power Cord Receptacle: This is where the onboard charger AC power cord plugs into the power base.

Main Circuit Breaker: The main circuit breaker is a safety feature built into your Jazzy. When the batteries and the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage to the motors and the electronics. If the circuit trips, allow your Jazzy to “rest” for approximately one minute. Next, push in the circuit breaker button, turn on the controller, and continue normal operation. If the main circuit breaker continues to trip repeatedly, contact your authorized Pride Provider.

Controller Connector: This is where the controller connects to the power base. The VSI controller uses a large 9-pin connector. The Remote Plus and the Europa use smaller, multi-pin communications cable connectors (not shown).

Charger Inhibit Connector: The VSI controller is equipped with a charger inhibit connector. The charger inhibit enables the onboard charger to disable the controller during charging. The charger inhibit connector is coded with colored dots. The dots are positioned so that you can align the flat side of the male connector with the flat side of the female connector before making the connection.

CAUTION! Failure to properly align the connectors can result in damage to the controller, the charger harness, and the connectors.

Charger Fuse: The charger fuse protects the ammeter from current overload. There are three fuses on the utility tray. The top one is the charger fuse. The bottom two are spares.

PowerActuator Connector and Lighting System Connector (VSI Only): This is where the power actuator connects to the controller. Standard lighting systems have a single-pin connector. Full lighting systems with the VSI controller use a 3-pin connector. Not shown.

Active-Trac Suspension (1121 Only)

The Jazzy 1121 is equipped withActive-Trac Suspension (ATS). ATS is a suspension system designed to make your Jazzy traverse different types of terrain and obstacles while maintaining smooth operation. WithATS, your front anti-tip wheels work in conjunction with your motor suspension to help you maneuver over obstacles in excess of three inches in height.

As your front anti-tip wheels come in contact with an obstacle, the front anti-tip wheel assembly is drawn upward. At the same time, your motors are forced downward. This allows the motors to push the Jazzy 1121 over an obstacle without the possibility of becoming “hung up” on the obstacle.

ATS also helps in day-to-day operating conditions. For instance, when you release the joystick, your Jazzy begins to slow down. As the chair slows down, the front anti-tip wheels will automatically drop toward the ground. This will reduce the forward tip that is typically encountered with center-wheel drive chairs.

18

www.pridemobility.com

Jazzy 1101/1121/Rev E/Jun03

Image 18
Contents Exeter, PA St. Catharines, on F E T Y G U I D E L I N E S Introduction Safety III EMI/RFI Jazzy 1101/1121N T R O D U C T I O N IntroductionInformation Exchange Pride Owners Club My Authorized Pride Provider IsPre-Ride Safety Check S a F E T YModifications Weight Limitations Tire InflationIncline Information Braking Information Cornering InformationFreewheel Mode Outdoor Driving SurfacesStationary Obstacles Steps, Curbs, etc EMI & RFI Inclement Weather Precautions Positioning BeltsAlcohol Reaching and BendingBatteries Removable PartsAre all power chairs susceptible to EMI/RFI? Frequently Asked Questions FAQsWhere do radio waves come from? I . E M I / R FWhat is the FDA doing about the problem? What should I do if my power chair moves unexpectedly? T H E J a Z Z Y 1 1 0 1 / 1 1 2 Jazzy 1121 1101 is similarVaries with user weight and terrain Jazzy 1121 Power Base 1101 is similar Electronics Tray Active-Trac Suspension 1121 OnlyManual Freewheel Lever To operate the single manual freewheel leverTo operate the dual manual freewheel levers Seat Installation To install the seatS S E M B L Y Comfort Adjustments C O M F O R T a D J U S T M E N T SArmrest WidthAdjustment To adjust the seatback angleSeatback Angle Adjustment ArmrestAngleAdjustment To change the armrest angleFootrest Angle Footrest Depth To adjust the footrest depthTo adjust the footrest angle Controller PositionTo adjust the ELR length To adjust the SFR lengthTo adjust the ELR angle Swing-away FootrestsTo adjust the anti-tip wheels Anti-Tip WheelsPower Elevating Seat Option Power Elevating Seat ActuatorPower Elevating Seat Operation To operate the power elevating seatTo use the swivel feature I . B a T T E R I E S a N D C H a R G I N G To charge the batteries using the onboard chargerTo charge the batteries using the off-board charger Batteries and ChargingHow often must I charge the batteries? Frequently Asked Questions FAQs How does the charger work?Can I use a different battery charger? Daily UseWhy do my new batteries seem weak? How can I get maximum range or distance per charge?What type of batteries should I use? What about public transportation? How can I ensure maximum battery life?How should I store my Jazzy and its batteries? What about shipping?VSI consists I I . O P E R a T I O NVSI Electronic Controller JoystickOn/Off Key Battery Condition MeterRed lights only lit or slow flash Charge battery as soon as Speed/Profile KeysCharger Inhibit Connector Actuator ConnectorController Connector Actuator Keys and Actuator Lights For Optional EquipmentVSI Error Codes Thermal RollbackPilot Controller On/Off ButtonPin Controller Connector Pin Charger Inhibit ConnectorSpeed Control Knob Flashing Diagnosis Solution Lights Pilot Trouble CodesRemote Plus Controller Remote Plus Master RemotePower Accessory Indicator Mode KeySpeed Setting Indicator Right/Left Turn Indicator KeysPower Accessories Speed SettingsTo select a speed setting Power ModuleSleep Mode Actuator Lighting Module Not ShownRemote Plus Trouble Codes Out Of Neutral At Power Up Dynamic DX ControllerEuropa Master Remote Magnetic Locking Area To enable the lockout the systemSystem Status Light Authorized Pride ProviderBattery Saver Feature To change the drive mode programDrive Mode and Actuator Display also Remote Status Display Drive Program Select KeyFlashcode Sequence Diagnosis Solution Trouble CodesC a R E a N D M a I N T E N a N C E Care and MaintenanceTemperature Should your Jazzy come in contact with waterTo check the brakes Daily ChecksWeekly Checks To calibrate the joystick Remote Plus onlyYearly Checks Cleaning Instructions Tire/Wheel ReplacementMonthly Checks StorageBattery Replacement To replace the batteriesCorrective Maintenance Motor BrushesTo inspect orreplace the motorbrushes P T I O N a L a C C E S S O R I E S W a R R a N T Y T E S Quality Control