V I I I . O P E R A T I O N
Actuator Lighting Module (Not Shown)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power interface between the power module, the lights, and/or the power seat actuator.
Sleep Mode
Your Remote Plus controller has a sleep mode feature. Sleep mode is a
Thermal Rollback
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors, power module, and remote. In the event that any of them become excessively hot (above 122° F), motor voltage is reduced. For every degree above 122° F, the voltage is reduced by 5 volts. This reduces your power chair’s speed and allows the electrical components to cool down. When the temperature returns to a safe level, your power chair resumes its normal speed.
Remote Plus Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with your power chair.The battery condition meter has ten lights. The lights provide information by the number of lights that are flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly flashing meter. When you get a trouble code, contact your authorized Pride Provider.
FLASHING LIGHTS | DIAGNOSIS | SOLUTION |
|
|
|
10 | High Battery Voltage | Check batteries. |
|
|
|
9 | Solenoid Brake Fault | Check motor/brake wiring. |
|
|
|
8 | Possible Controller Fault | See authorized Pride Provider. |
|
|
|
7 | Possible Joystick Fault | SeeauthorizedPrideProvider. |
|
|
|
6 | Inhibit Active | Unplug charger. Check connections. |
|
|
|
5 | Right Motor Wiring Fault | Check right motor wiring. |
|
|
|
4 | Right Motor Disconnected | Check right motor wiring. |
|
|
|
3 | Left Motor Wiring Fault | Check left motor wiring. |
|
|
|
2 | Left Motor Disconnected | Check left motor wiring. |
|
|
|
1 | Low Battery Voltage | Check batteries/battery wiring. |
|
|
|
42 | www.pridemobility.com | Jazzy 1101/1121/Rev E/Jun03 |