Panasonic CZ-RD515U service manual USING THE 1-HOUROFF TIMER, Adjusting The Airflow Direction

Page 22
 USING THE 1-HOUR OFF TIMER

1. 1-Hour OFF Timer USING THE 1-HOUR OFF TIMER  ADJUSTING THE AIRFLOW DIRECTION

1. 1-Hour OFF Timer

This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.

The Manual background indicator in the display indicates that this function is operating.

Setting procedure:

Manual background ADJUSTING THE AIRFLOW DIRECTION Manual background

The vertical airflow can be adjusted by moving the flap with the remote controller. Do not move the flap with your hands. Confirm that the remote controller has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.

A. Sweep function

The flap starts moving up and down to deliver air over the sweep range.

Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button.

appears in the display.

Cancellation procedure:

Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.

The 1-Hour Timer function is now cancelled and the unit operates normally.

NOTE

B. Setting the airflow manually

Referring to the above illustration, use the FLAP button to set the airflow direction within the range used during the heating, cooling, or dehumidifying operation.

SWEEP

COOL

DRYSWEEP FAN

HEAT

If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.

It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later.

2.Operation together with the daily ON/OFF repeat timer

The 1-Hour OFF Timer setting is given priority over the DAILY ON/ OFF REPEAT setting.

NOTE

The flap automatically closes when the unit is off.

During the heating operation, the fan speed will be very low and the flap will be in the horizontal position (position Manual background) until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote controller.

Manual backgroundManual background CAUTION

Use the FLAP button on the remote controller to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote controller and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again.

Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down.

10

Image 22
Contents Model No CZ-RD515UWIRED REMOTE CONTROLLER Product Code NoSAFETY PRECAUTIONS which may cause a unit breakdown FUNCTIONS Table of ContentsINSTALLATION INSTRUCTIONS Operating Instructions1. SPECIFICATIONS 1 Ceiling cassette type 2. APPLICABLE INDOOR UNITS3. FUNCTIONS 2 Wall mounted type4-1. Self-DiagnosticsProcedure 4. SELF-DIAGNOSTICSPROCEDURE HIGH POWER lamp 4-2. Self-DiagnosticsTable Ceiling Cassette TypeTIMER lamp REMOTE CONTROL receiverOPERATION button REMOTE CONTROL receiver 4-3. Self-DiagnosticsTable Wall Mounted Type1 OPERATION lamp 2 TIMER lamp 3 QUIET lamp DIAGNOSIS CONTENTSDIAGNOSIS CONTENTS 4-4. Self-DiagnosticsTable Wall Mounted Type2 TIMER lamp INDOOR UNITPage APPENDIX A Operating Instructions CZ-RD515UOperating Instructions Wired Remote Controller Model No. CZ-RD515USAFETY PRECAUTIONS FEATURESCONTENTS PRODUCT INFORMATIONELECTRICAL REQUIREMENTS INSTALLATION LOCATIONSAFETY INSTRUCTIONS AvoidTimer and Present Time setting buttons REMOTE CONTROLLERTemperature setting buttons TEMP DisplayAUTO 1 HR. TIMER button 1-HOUROFF TIMERTIMER SELECT button HEATREMOTE CONTROLLER DISPLAY Symbolsonly for COOL/DRY/HEAT Model OPERATION WITH THE REMOTE CONTROLLER1.Automatic Operation 2. Manual OperationRemote Controller 3. Adjusting the Fan SpeedPower failure during operation Remote Controller Display2. How to set the OFF time SETTING THE TIMER1. How to set the present time 3. How to set the ON timeADJUSTING THE AIRFLOW DIRECTION USING THE 1-HOUROFF TIMER1. 1-HourOFF Timer Page APPENDIX B INSTALLATION INSTRUCTIONS CZ-RD515U CZ-RD515URemote controller installation guidelines INSTALLATION INSTRUCTIONS Wired Remote ControllerParts supplied with the remote controller How to install the remote controllerFig. 2-a A. Installing with in-walljunction boxB. Installing directly onto the wall Fig. 2-bFig. 8-a How to wire the remote controllerFig. Fig. 8-bHow to Test Run the Air Conditioner Page APPENDIX C CZ-RC515UParts included in the package INSTALLATION INSTRUCTIONS Connection KitInstalling the connection kit Fig. 2aFig. 4c Fig. 4bFig. 4a Fig. 5aB. 18000 BTU and 24000 BTU inverter models How to Test Run the Air Conditioner Fig. FigPage APPENDIX D INSTALLATION INSTRUCTIONS CZ-RC515UAParts included in the package Installing the connection kitINSTALLATION INSTRUCTIONS Connection Kit LUHKDUQHVV Wire harnessRQQHFWRU% KDUQHVV 5HLQVWDOOWKHHOHFWULFDOERFRYHU Wire harness ClampOpen hole Wire harness ODPS 1RLVHILOWHU LUHKDUQHVV7URXEOHVKRRWLQJ How to Test Run the Air ConditionerFig. Fig Page DC1111-0
Related manuals
Manual 42 pages 22.63 Kb

CZ-RD515U specifications

Panasonic has consistently been a leader in providing effective HVAC solutions, and the CZ-RD515U model exemplifies this dedication. This advanced remote controller is designed to enhance the user experience when managing Panasonic’s air conditioning and heat pump systems.

One of the standout features of the CZ-RD515U is its versatility. The remote can control multiple indoor units, making it suitable for both residential and commercial applications. The device supports a variety of operation modes, including cooling, heating, and auto mode, allowing users to tailor the climate control to their specific needs.

The unit boasts a clear LCD display that shows operational status, temperature settings, and mode selection, ensuring easy readability from a distance. Users can effortlessly adjust temperature settings to maintain an optimal comfort level using intuitive buttons. Additionally, the remote features a timer function, allowing users to program start and stop times for their HVAC systems, which helps in saving energy and improving efficiency.

Another significant technology integrated into the CZ-RD515U is the super quiet operation mode. This feature allows users to set their air conditioning system to operate at lower noise levels, making it ideal for nighttime use or quiet zones. Furthermore, the remote controller includes a "powerful" function, which provides a temporary boost in power to reach desired temperatures more quickly, enhancing overall comfort in the space.

Panasonic has also incorporated a user-friendly design into the CZ-RD515U, with a lightweight structure and ergonomic grip, making it easy to hold and operate. The remote is equipped with a protective cover to safeguard against dust while not in use. Each remote can function under a considerable distance range, providing convenience in larger spaces.

Moreover, the CZ-RD515U takes advantage of advanced wireless communication, ensuring reliable control without the hindrances of wired connections. This flexibility underlines Panasonic’s commitment to user-centric design, merging functionality with cutting-edge technology to deliver superior comfort solutions.

Ultimately, the Panasonic CZ-RD515U stands out for its thoughtful features and functionalities, making it a reliable and efficient option for controlling your heating and cooling systems effortlessly. Its advanced capabilities, ease of use, and quiet operation make it a valuable addition to any home or business environment.