Specifications

MECHANICAL

Case dimensions: 11.5” W x 12.5” H x 3.5” D

ELECTRICAL

Voltage: 16-24 Volts AC or 12-24 Volts DC

Current: 850 mA maximum @ 12 Volts DC

Backup Battery: 12 Volt DC

Outputs: Relay Channels A-D

Form “C” 3 Amps @ 30 Volts maximum

Inputs: Four normally closed door sense inputs

Four normally open request-to-exit inputs

Two WIEGAND reader inputs

Two PBUS inputs

Network: Three-wire network

ENVIRONMENTAL

Temperature: -22°F to 149°F (-30°C to 65°C)

Humidity: 5% to 95% non-condensing

Troubleshooting

System completely dead

1.No power from transformer. Check voltage at AM3Plus transformer terminals.

System will not answer an incoming call

1.Automatic telephone answer disabled.

2.AM3Plus telephone line trouble.

3.ACM-1 Modem not installed or not installed correctly (check that all the modem pins are correctly in the modem socket).

Entry code will not activate relay

1. Entry code not set up for proper relay.

Remote PBUS device does not work

1.Check remote device address switch setting.

2.Check remote device for power.

Remote keypad will not activate a relay

1.Entry code is not assigned.

2.Keypad may be in lockout from too many incorrect attempts. Wait one minute for lockout to clear and try again.

Transmitter does not activate relay

1.Transmitter button setting programmed to “no relay” (would effect all transmitters).

2.Transmitter block not enrolled.

3.Specifi c transmitter is deactivated in the system.

18

Image 18
Contents AM3Plus Introduction ContentsProgramming and Cardholder Maintenance OperationHardware Features Feature OverviewSoftware Highlights Accessory Overview Pbus Accessories Wiegand AccessoriesComponent Locations AM3PLUSWiring Diagram Relay RatingImportant Mounting Requirements AM3Plus Mounting Standard CabinetOutdoor Cabinet Gate Control Relay Output WiringDoor or Pedestrian Gate Control Request-to-Exit InputsBackup Battery Power, Battery, & Ground WiringPower Wiring Earth GroundImportant Telephone Wiring Tips Telephone WiringPbus Accessories Typical Telephone WiringWiegand Accessories RS-232 PortOptional Network Connections Network Configurations for Axnet ProgrammingNetwork Configuration for AccessBase2000 Programming Full ACCESSBASE2000 NetworkRS-485 Network Wiring Network Wiring with HubNetwork Daisy-chain Wiring System Controls Power-upProgram Mode PushbuttonsSystem Diagnostics IndicatorsTroubleshooting SpecificationsLinear Limited Warranty FCC NoticeCopyright 2007 Linear LLC