Specifications
MECHANICAL
Case dimensions: 11.5” W x 12.5” H x 3.5” D
ELECTRICAL
Voltage:
Current: 850 mA maximum @ 12 Volts DC
Backup Battery: 12 Volt DC
Outputs: Relay Channels
Form “C” 3 Amps @ 30 Volts maximum
Inputs: Four normally closed door sense inputs
Four normally open
Two WIEGAND reader inputs
Two PBUS inputs
Network:
ENVIRONMENTAL
Temperature:
Humidity: 5% to 95%
Troubleshooting
System completely dead
1.No power from transformer. Check voltage at AM3Plus transformer terminals.
System will not answer an incoming call
1.Automatic telephone answer disabled.
2.AM3Plus telephone line trouble.
3.
Entry code will not activate relay
1. Entry code not set up for proper relay.
Remote PBUS device does not work
1.Check remote device address switch setting.
2.Check remote device for power.
Remote keypad will not activate a relay
1.Entry code is not assigned.
2.Keypad may be in lockout from too many incorrect attempts. Wait one minute for lockout to clear and try again.
Transmitter does not activate relay
1.Transmitter button setting programmed to “no relay” (would effect all transmitters).
2.Transmitter block not enrolled.
3.Specifi c transmitter is deactivated in the system.
18