Linear installation instructions AM3Plus Mounting, Standard Cabinet, Outdoor Cabinet

Page 8

AM3Plus Mounting

Standard Cabinet

The AM3Plus cabinet is designed to be mounted directly to a wall or fl at surface.

Wiring access for power, telephone, earth ground, control output must be available at the mounting location. For easier wiring, choose a well lit location. Wiring access for remote accessory cables must also be available at the mounting location.

1.Flip the cabinet’s cover up to unlock the hinges and remove the cover from the case.

2.To make cabinet mounting easier, the AM3Plus can be removed from the cabinet (optional).

3.If using conduit for wiring, punch out the selected cabinet wiring knockouts.

4.Use the cabinet as a template and mark the locations for the four cabinet mounting screws in the keyhole slots.

5.Mark the wiring access slot if the wiring is being routed from behind the cabinet.

6.Use a hole saw to cut out the location for the wiring access slot (if used).

7.Use four screws and appropriate screw anchors to mount the cabinet to the wall.

8.If the AM3Plus was removed to mount the cabinet, replace the AM3Plus.

9.After the installation’s wiring and programming are complete, replace the cabinet’s cover and secure it with the two screws provided.

Outdoor Cabinet

To protect the unit outdoors, the AM3Plus can be mounted inside a Linear Model CAB-3 (P/N ACP000913) outdoor metal cabinet.

Wiring access for power, telephone, earth ground, control output must be available at the mounting location. For easier wiring, choose a well lit location. Wiring access for remote accessory cables must also be available at the mounting location.

1.Open the cabinet’s cover and push it in to latch it open.

2.Punch out the selected cabinet wiring knockouts.

3.Use the cabinet as a template and mark the locations for the four cabinet mounting screws.

4.Use four screws and appropriate screw anchors to mount the cabinet to the wall.

5.Mount the AM3Plus inside the cabinet with four 6-32 screws.

6.After the installation’s wiring and programming are complete, lower the cabinet’s cover and secure it with a lock.

FOR CONDIUT WIRING,

PUNCH OUT REQUIRED

KNOCKOUTS AND

INSTALL 3/4" CONDUIT

HUBS IN HOLES

CONDUIT

KNOCKOUTS

FOR CONDUIT WIRING,

REMOVE ANY CABINET

KNOCKOUTS BEFORE

MOUNTING THE CABINET

USE THE CABINET BOTTOM AS

A TEMPLATE TO MARK THE

FOUR KEYHOLE MOUNTING

HOLES

FOR RECESSED WIRING,

MARK WIRING SLOT,

THEN CUT OUT HOLE

WITH DRYWALL SAW

USE THE APPROPRIATE

HARDWARE TO MOUNT

THE CABINET

AM3PLUS MOUNTS IN

CAB-3 CABINET WITH

FOUR 6-32 SCREWS

CAB-3 CABINET

8

Image 8
Contents AM3Plus Contents Programming and Cardholder MaintenanceIntroduction OperationSoftware Highlights Hardware FeaturesFeature Overview Accessory Overview Pbus Accessories Wiegand AccessoriesComponent Locations AM3PLUSWiring Diagram Relay RatingImportant Mounting Requirements Outdoor Cabinet AM3Plus MountingStandard Cabinet Relay Output Wiring Door or Pedestrian Gate ControlGate Control Request-to-Exit InputsPower, Battery, & Ground Wiring Power WiringBackup Battery Earth GroundTelephone Wiring Pbus AccessoriesImportant Telephone Wiring Tips Typical Telephone WiringWiegand Accessories RS-232 PortOptional Network Connections Network Configurations for Axnet ProgrammingNetwork Configuration for AccessBase2000 Programming Full ACCESSBASE2000 NetworkNetwork Daisy-chain Wiring RS-485 Network WiringNetwork Wiring with Hub Power-up Program ModeSystem Controls PushbuttonsSystem Diagnostics IndicatorsTroubleshooting SpecificationsLinear Limited Warranty FCC NoticeCopyright 2007 Linear LLC