ResMed S9 Auto 25, VPAP S, AutoSet CS manual Getting started, Cleaning and maintenance

Page 5

Getting started

1.Make sure the power is connected.

2.Adjust the ramp time if required.

3.Fit your mask as described in your mask user guide.

4.To start therapy, simply breathe into the mask and/or press .

5.Lie down and arrange the air tubing so that it is free to move if you turn in your sleep.

6.To stop treatment at any time, remove your mask and/or press .

Notes:

If your clinician has enabled SmartStart your device will start automatically when you breathe into the mask and stop automatically when you remove the mask.

If power is interrupted during treatment, the device automatically restarts therapy when power is restored.

Cleaning and maintenance

Daily:

Remove the air tubing by pulling on the finger grips on the cuff. Hang it in a clean, dry place until next use.

Notes:

Do not hang the air tubing in direct sunlight as it may harden over time and eventually crack.

Do not wash the air tubing in a washing machine or dishwasher.

Weekly:

1.Remove the air tubing from the device and the mask.

2.Wash the air tubing in warm water using mild detergent.

3.Rinse thoroughly, hang, and allow to dry.

4.Before next use, reconnect the air tubing to the air outlet and mask.

Monthly:

1.Wipe the exterior of the device with a damp cloth and mild detergent.

2.Check the air filter for holes and blockage by dirt or dust. Replace the air filter if necessary.

Replacing the air filter:

Replace the air filter every six months (or more often if necessary).

1.Remove the air filter cover from the back of the device.

2.Remove and discard the old air filter.

3.Insert a new ResMed air filter ensuring that it is sitting flat in the air filter cover.

4.Replace the air filter cover.

Notes:

Ensure the air filter and air filter cover are fitted at all times.

Do not wash the air filter. The air filter is not washable or reusable.

3 English

Image 5
Contents Vpap ST Page S9 Vpap S indications for use S9 Vpap ST indications for useS9 AutoSet CS indications for use S9 Auto 25 indications for useNavigating the menus Masks and humidifiers SetupControl panel Getting started Cleaning and maintenanceProblem/Possible cause TroubleshootingProblem/Possible cause Solution Will not be re-displayed SD card Technical specificationsDevice can be higher than the temperature of the room Pneumatic flow path SymbolsEnvironmental information Limited warrantyServicing English English English
Related manuals
Manual 2 pages 23.72 Kb

AutoSet CS, S9 Auto 25, VPAP S specifications

ResMed, a leader in sleep and respiratory care, has developed a range of advanced devices designed to enhance the quality of life for those suffering from sleep apnea and other respiratory conditions. Among these, the ResMed AutoSet CS, S9 Auto 25, and VPAP S stand out due to their innovative features and technologies aimed at providing personalized therapy.

The ResMed AutoSet CS is engineered to offer adaptive therapy for patients facing complex sleep apnea. This device utilizes advanced algorithms that continuously assess the patient’s breathing patterns throughout the night. By analyzing flow limitation, apnea, and hypopnea events in real time, it adjusts the pressure delivered to ensure optimal airflow. The AutoSet CS is particularly beneficial for those who experience varying levels of airway obstruction, providing a tailored response that improves overall comfort and efficacy.

The S9 Auto 25 is another remarkable device, distinguished by its user-friendly interface and sleek design. This auto-titrating CPAP device automatically adjusts pressure levels based on the patient’s needs throughout the night. It incorporates ResMed’s QuietAir technology, ensuring a quieter operation, which promotes a peaceful sleep environment. Additionally, the S9 Auto 25 features an integrated humidification system that delivers moisture to the airflow, preventing dryness and irritation, which are common complaints among CPAP users.

The VPAP S represents ResMed’s commitment to providing bi-level positive airway pressure therapy. It offers two distinct pressure settings: one for inhalation and a lower setting for exhalation. This dual-pressure mechanism allows for a more natural breathing experience, particularly beneficial for those with more severe forms of apnea. The VPAP S also features Easy-Breathe technology, which smooths out pressure transitions, making it easier for patients to breathe naturally and comfortably through the night.

Key characteristics shared by these devices include advanced data tracking and reporting capabilities. Users can access valuable insights into their therapy through user-friendly interfaces or companion apps, facilitating better management of their condition. Each model is designed with portability in mind, ensuring patients can receive effective therapy whether at home or on the go. With ResMed’s commitment to innovation, the AutoSet CS, S9 Auto 25, and VPAP S are pivotal in transforming the landscape of sleep apnea treatment, providing patients with effective, comfortable, and adaptable therapy solutions.