LG Electronics QHW 30, QHW 6, QHW 15 manual Parameters

Page 16

QHW digital weighing scales user’s guide

SECTION 9 PARAMETERS

The scale has 6 parameters that can be set by the user. These allow the user to set the scale to:

Display the weight in other increments of weight to minimize the affects of vibration, wind or other environmental conditions.

Control the back light on the display. It may be necessary to turn the backlight off to maximize battery life.

Set the Accumulation to Automatic, manual or set the RS-232 interface to continuously print the weight.

Set whether accumulation when print

Set auto zero range

Select another weighing unit than the standard.

To set parameters press the FUNC and PRINT keys at the same time.

The display will show "Inc xx" The first value shown is the default scale increment

value. To select a different increment value press the TARE/Ï key to change the value then press the ZERO/ENTER key.

For example on a 15kg scale the standard increment is 0.5g, the value can be changed to 1.0g or 2.0g.

The next parameter is control of the backlight. The standard is to have the backlight operate automatically, turning off when the scale is not used. The backlight can be set to be "EL On" , "EL Au" (Automatic) or "EL Off". The maximum battery life is achieved with the backlight turned off.

Press the TARE/Ï key to change the value then press the ZERO/ENTER key.

Automatic accumulation is next. With "Au On" the memory will accumulate the

weight automatically, "Au

Off" will enable the manual accumulation and with "P

Cont" set the RS-232

interface will send the weight continuously and the

accumulation function is disabled.

Press the TARE/Ï key to change the value then press the ZERO/ENTER key.

Whether accumulation when print is next, With “ACC ON” when you print it will accumulation, “ACC OF” will only print without accumulation.

Press the TARE/Ï key to change the setting then press the ZERO/ENTER key.

Auto zero range is next, you can select 0.5d, 1d, 2d and 4d.

Press the TARE/Ï key to change the setting then press the ZERO/ENTER key.

The displayed unit of weight is set next. The scales are normally calibrated and display in kilograms, however they will show the weight in grams, ounces or pounds and selected by this function.

Press the TARE/Ï key to change the value then press the ZERO/ENTER key.

When the scales are set to display in other units of weight the accumulation function is still keeping the weight in kilograms.

- 12 -

Image 16
Contents QHW series Page Contents Page Introduction Specifications QHWInstallation General InstallationKEY Descriptions Zero orTkglb DisplaysOperation Zeroing the DisplayParts Counting Accumulated Total Manual AccumulationAutomatic Accumulation Battery Operation RS-232 Output Parameters Calibration Linear calibrateError Codes ZERO/ENTER