Whirlpool Petra Collection owner manual Discharge Pump Installation Optional

Page 15

Discharge Pump Installation (Optional)

ON/OFF DISCHARGE SWITCH

 

POWER CORD

 

 

MUST BE PLACED HIGHER THAN WATER LEVEL

CONVERTER BOX

 

 

WATER LEVEL

AIR TUBING

Outlet

 

Tub

Check Valve must be installed to prevent back flow

AIR VENT HOSE

A

B

ATTACHMENT PIPE

L-TRAP

Main Drain Pipe

DISCHARGE PUMP

- Outlet from drain pump must be placed

 

on top of the main drain pipe

To prevent the possible air lock, B has to higher than A

- Do not use flexible pipe for drain

FAQ

1) Pump hums but does not drain the water out

-Air Lock : Piping elevation must be above discharge pump outlet so that air can be released

-Turn pump on, wait 5 seconds, turn pump off. Repeat 10 times. If the air is not repleased, detach attachment pipe and re-attach

Quick Tip: Use a plunger to release the air lock

2)Pump does not turn on - Check the power source

- Check if the air tubing is properly attached from the switch to the converter box - Check attachment pipes throughly for debris

3)Noise when turn on

- Foreign object may be lodged - Disassemble and remove debris or particles

15

Image 15
Contents Pedicurespas by Standard Whirlpool Jet Sanijet Pipeless Optional Precautions Important PrecautionsInspection Electrical ServiceInstallation Summary Important ConsiderationsPetra 700 Petra 450, 350R, 350V Important Assembly Installation Rear View Wall Electrical Connections Testing the Foot spaCleaning and Care of Your Foot spa Plumbing ConnectionsMaintenance DisassemblyAssembly Troubleshooting Guide Assembly of the jet and maintenance Cleaning/ Flushing the inner whirlpool systemTrouble Shooting Guide Discharge Pump Installation Optional Lubrication USA, INC MULTI-COLOR LED SPA Light Plumbing Accessories