Discharge Pump Installation (Optional)
ON/OFF DISCHARGE SWITCH |
| POWER CORD |
|
| |
MUST BE PLACED HIGHER THAN WATER LEVEL | CONVERTER BOX | |
|
| |
WATER LEVEL | AIR TUBING | Outlet |
| ||
Tub | Check Valve must be installed to prevent back flow | |
AIR VENT HOSE | A | B |
ATTACHMENT PIPE
Main Drain Pipe
DISCHARGE PUMP | - Outlet from drain pump must be placed |
| on top of the main drain pipe |
To prevent the possible air lock, B has to higher than A | - Do not use flexible pipe for drain |
FAQ
1) Pump hums but does not drain the water out
-Air Lock : Piping elevation must be above discharge pump outlet so that air can be released
-Turn pump on, wait 5 seconds, turn pump off. Repeat 10 times. If the air is not repleased, detach attachment pipe and
Quick Tip: Use a plunger to release the air lock
2)Pump does not turn on - Check the power source
- Check if the air tubing is properly attached from the switch to the converter box - Check attachment pipes throughly for debris
3)Noise when turn on
- Foreign object may be lodged - Disassemble and remove debris or particles
15