Panasonic EW3002 operating instructions Care and Maintenance, Storing the Monitor

Page 9

About the Precise Logic™ Measurement System

The blood flow (pulse wave) which influences blood pressure monitors varies according to the conditions of the blood vessels and the structure of the arm, making measurements by conventional methods difficult in some cases. For more consistent, accurate results, this device employs a Precise Logic™ measurement system that verifies both the height and width of the pulse wave in order to reliably measure blood pressure.

Panasonic Technology

Double Check Measurement System

Checks both Pulse Height and Pulse Width

Old Technology

Relies only on Pulse

Height

By using the Precise Logic™ measurement system, measurement reliability and accuracy have been improved.

Care and Maintenance

1.Use a dry, soft cloth to clean the device. If desired, use a cloth lightly dampened with tap water and a mild detergent to clean the device. DO NOT use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff.

2.When the unit will not be used for a long time (30 days or more), be sure to remove the batteries. Otherwise, the batteries may leak and damage the unit.

Storing the Monitor

Fold the pressure cuff as shown in Fig. 17 and place the monitor into the hard carrying case.

Fig. 17

1

2

3

15

16

Image 9
Contents Operating Instructions Table of Contents Important Instructions Before Use Basics of Blood PressurePrecautions to Ensure Safe, Reliable Operation Battery cover When to Change BatteriesName and Function of Each Product Part Inserting/Replacing Batteries Positioning the Pressure Cuff Taking measurements while sitting down Taking measurements while lying down Measuring Your Blood Pressure ErrorDeleting Data Recalling Stored DataStoring the Monitor Care and MaintenanceTroubleshooting Display Status before error Check pointsSymptom Possible cause Specifications Índice Instrucciones importantes antes de usar la unidad Conocimientos básicos de la presió n arterialPage Introducció n/cambio de las pilas Nombre y funció n de cada parteCuá ndo sustituir las pilas NotasTomas de medidas sentado Colocació n de la banda de presió nTomas de medidas tumbado Posició n correcta para medir la presió n arterialNota Medida de su presió n arterialBorrado de datos Recuperació n de datos almacenadosCuidados y mantenimiento Para guardar el monitorAcerca del sistema de medida Precise Logic Localizació n y solució n de problemas Visualizació n Estado antes del errorSíntomas Causa posible Especificaciones