Open window venting The end of the tube should be directed downwards to prevent warm and moist air from condensing in the room or in the dryer.

!Ensure that the dryer is adequately ventilated and that the end of the vent tube is not directed towards the air intake duct.

!The vent tube must always be fitted for optimum performance.

!Make sure that the vent tube and air intake vents

are not obstructed or blocked.

!The dryer must not recycle exhaust air.

!Misusing a tumble dryer may create a fire hazard.

!Do not discharge exhaust air into a flue which is used for exhaust fumes from other appliances that burn gas or other fuels.

!Do not discharge the exhaust air into an extraction system or any duct with an extractor fan. This will affect the way the thermal controls operate and can result in a fire hazard.

Electrical connection

Make sure of the following before you insert the plug into the electrical socket:

The socket must be grounded.

The socket must be able to sustain the machine’s maximum power, which is indicated on the rating label (see Dryer Description).

Power voltage must be within the values indicated on the rating label (see Dryer Description).

The socket must be compatible with the dryer’s plug. Should this not be the case, replace the plug or the socket.

!The dryer must not be installed outdoors, even if the space is sheltered. It can be very dangerous if exposed to rain or storms.

!Once installed, the dryer’s electrical wire and plug must be within reach.

TD4002AUS Issue 2

!Do not use extension cords

!The power cord must not be bent or squashed.

! The power cord should be checked periodically and

GB

replaced by a cord specially prepared for this dryer

 

and fitted only by authorised technicians. (see

 

Service). New or longer power cords are supplied at

 

an extra charge by authorised dealers.

 

!Ensure that any portable outlet or extension lead is positioned so that it is not subjected to any splashing or ingress of moistures

!The manufacturer denies any responsibility should any of these rules not be followed.

!If in doubt about any of the above consult a qualified electrician

Levelling your dryer

The dryer must be installed level for correct operation. When you have installed your dryer in its final location check that it is level first side-to-side, then front to back.

If the dryer is not level, use a wooden block to support it while adjusting the two front legs up or down until your dryer is level.

Before you start using your dryer

Once you’ve installed your dryer and before you use it, clean the inside of the drum to remove any dust that could have accumulated during transportation.

4

Image 4
Contents Instruction booklet Tumble DryerImportant Information Where to put your dryer InstallationVentilation Electrical connection Dryer Description Timed Dry Delay TimerTime to End Start and Programmes TD4234FUV Issue Essential Programmes Programmes TableCottons Bed & BathEssential Programmes Start and Programmes TD4235FUV IssueExclusive Programmes Programmes Table Start and Programmes Start and Programmes Extra Programmes Programmes TableTime Delay Programmes knobOption Buttons/ Lights Progress Drying, Cool tumble, IconsLaundry Sorting your laundrySpecial clothing items Drying timesGeneral safety GB Switching off the electricity Clean the filter after each cycleCleaning the drum Cleaning the dryerProblem Possible causes / Solutions TroubleshootingDisplay briefly shows every 6 seconds What to tell the Service Centre Before calling the Service CentreSpare Parts English, All Logos to be Ariston