Olympus X-Press V, StarTip V manual Spacifications

Page 3

Spacifications

Model

Shape of the distal end

Distal tip diameter

Portion Diameter

Working length

Compatible guidewire

PR-V414Q

Short taper

4.5Fr

 

1700mm

0.89mm(0.035inch)

PR-V416Q

Standard

4.0Fr

 

 

0.89mm(0.035inch)

PR-V418Q

Short taper

3.5Fr

 

 

0.64mm(0.025inch)

PR-V420Q

Long taper

3.5Fr

2.1mm

1950mm

0.64mm(0.025inch)

PR-V427Q

Slit

2.5Fr

 

0.89mm(0.035inch)

 

 

PR-V434Q

Taper

4.0Fr

 

 

0.89mm(0.035inch)

PR-V435Q

Taper

3.5Fr

 

 

0.64mm(0.025inch)

PR-V223Q

Ball Tip

6.0Fr

2.0mm

 

0.89mm(0.035inch)

Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer.

Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan

Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany 2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.

6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U.S.A Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England

491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373 Room 1520-1527, Ocean Centre, 5 Canton Road, Tsimshatsui, Kowloon, Hong Kong Room.1401, East Tower, Gong Yuan No6 Royal Palace, No6 Gon YuanXijie, JianGuoMenNei, DongCheng District, Beijing, 100005, China 117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia

31 Gilby Road, Mount Waverley, VIC., 3149, Australia

Printed in Japan F1086SB-3-0804

Image 3
Contents Single Use Cannula Smooth cannulation of even minor or constricted papilla Expanded guidewire compatibilityExcellent visibility under fluoroscopy Wide selection of cannulaeSpacifications Single Use 3-Lumen Extraction Balloon Tapered sheath design Multiple balloon sizingTriple-lumen design allows for Easier cannulationEasier cannulation Tapered sheath design Three pre-measured syringes for reliable inflationDual radiopaque bands for position confirmation Injection port Above Single Use Retrieval Basket Rotation mechanism Bullet-shaped tip Wire guided ability forFour-wire basket Design for Versatile retrieval Superior insertion capabilityBML-110A-1 Page Distal marking on the sheath for Easy identification of ports Efficient cannulation capabilityPre-curved distal end For easier knife positioningCompatible guidewire Tip length Disposable Guidewire Two-step markers ensure visibility Endoscopic field of view Scope forcepsLinearGuideV in place 400mm Ring-marker section Spiral-marker section Specially coated to insure smooth wire manipulationOuter diameter