Olympus StarTip V, X-Press V manual BML-110A-1

Page 10

Spacifications

Model

Basket type

Rotatable/Guidewire type

Working length

Opening width

Minimum channel size Compatible guidewire

FG-V401QR

8wire type

Rotatable type

1950mm

20mm

2.8mm

-

FG-V402QR

4wire type

Rotatable type

1950mm

22mm

2.8mm

-

FG-V411Q

8wire type

Guidewire type

1950mm

20mm

3.7mm

0.89mm(0.035inch)

FG-V412Q

4wire type

Guidewire type

1950mm

22mm

3.7mm

0.89mm(0.035inch)

BML-110A-1

An emergency device, this is only to be used in the unlikely event of basket impaction due to an extremely hard calculus.

Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer.

Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan

Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany 2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.

6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U.S.A Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England

491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373 Room 1520-1527, Ocean Centre, 5 Canton Road, Tsimshatsui, Kowloon, Hong Kong Room.1401, East Tower, Gong Yuan No6 Royal Palace, No6 Gon YuanXijie, JianGuoMenNei, DongCheng District, Beijing, 100005, China 117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia

31 Gilby Road, Mount Waverley, VIC., 3149, Australia

Printed in Japan F1091SB-3-0804

Image 10
Contents Single Use Cannula Wide selection of cannulae Expanded guidewire compatibilityExcellent visibility under fluoroscopy Smooth cannulation of even minor or constricted papillaSpacifications Single Use 3-Lumen Extraction Balloon Easier cannulation Multiple balloon sizingTriple-lumen design allows for Tapered sheath designThree pre-measured syringes for reliable inflation Easier cannulation Tapered sheath designDual radiopaque bands for position confirmation Injection port Above Single Use Retrieval Basket Superior insertion capability Wire guided ability forFour-wire basket Design for Versatile retrieval Rotation mechanism Bullet-shaped tipBML-110A-1 Page Distal marking on the sheath for For easier knife positioning Efficient cannulation capabilityPre-curved distal end Easy identification of portsCompatible guidewire Tip length Disposable Guidewire Scope forceps Two-step markers ensure visibility Endoscopic field of viewLinearGuideV in place 400mm Specially coated to insure smooth wire manipulation Ring-marker section Spiral-marker sectionOuter diameter