Olympus X-Press V, StarTip V manual Injection port Above

Page 7

Spacifications

Model

B-V231P-A

B-V231P-B

Injection port

Above

Below

Balloon diameter

8.5mm/11.5mm/15.0mm

8.5mm/11.5mm/15.0mm

Sheath

Distal end 5.5Fr/Proximal end 7Fr

Distal end 5.5Fr/Proximal end 7Fr

Working length

1900mm

1900mm

Minimum channel size

2.8mm min

2.8mm min

Compatible guidewire

0.89mm(0.035inch)

0.89mm(0.035inch)

Radiopaque band

One band at the distal end and one band

One band at the distal end and one band

 

at the proximal end of balloon

at the proximal end of balloon

Syringes

Three(3)syringes in different sizes are

Three(3)syringes in different sizes are

 

contained in the balloon package

contained in the balloon package

Specifications, design and accessories are subject to change without any notice or obligation on the part of the manufacturer.

Shinjuku Monolith, 3-1 Nishi-Shinjuku 2-chome, Shinjuku-ku, Tokyo 163-0914, Japan

Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-18, 20097 Hamburg, Germany 2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.

6100 Blue Lagoon Drive, Suite 390 Miami, Florida 33126-2087, U.S.A Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England

491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373 Room 1520-1527, Ocean Centre, 5 Canton Road, Tsimshatsui, Kowloon, Hong Kong Room.1401, East Tower, Gong Yuan No6 Royal Palace, No6 Gon YuanXijie, JianGuoMenNei, DongCheng District, Beijing, 100005, China 117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia

31 Gilby Road, Mount Waverley, VIC., 3149, Australia

Printed in Japan F1084SB-3-0804

Image 7
Contents Single Use Cannula Smooth cannulation of even minor or constricted papilla Expanded guidewire compatibilityExcellent visibility under fluoroscopy Wide selection of cannulaeSpacifications Single Use 3-Lumen Extraction Balloon Tapered sheath design Multiple balloon sizingTriple-lumen design allows for Easier cannulationThree pre-measured syringes for reliable inflation Easier cannulation Tapered sheath designDual radiopaque bands for position confirmation Injection port Above Single Use Retrieval Basket Rotation mechanism Bullet-shaped tip Wire guided ability forFour-wire basket Design for Versatile retrieval Superior insertion capabilityBML-110A-1 Page Distal marking on the sheath for Easy identification of ports Efficient cannulation capabilityPre-curved distal end For easier knife positioningCompatible guidewire Tip length Disposable Guidewire Scope forceps Two-step markers ensure visibility Endoscopic field of viewLinearGuideV in place 400mm Ring-marker section Spiral-marker section Specially coated to insure smooth wire manipulationOuter diameter