Trane 2TWA0, 2TWA2 manual 2TWA Outline Drawing, Models Base

Page 6

Installer’s Guide

2TWA OUTLINE DRAWING

Note: All dimensions are in MM (Inches).

MODELS

BASE

FIG.

A

B

C

D

E

F

G

H

J

K

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA0030A

2

2

730 (28-3/4)

724 (28-1/2)

651(25-5/8)

3/4

5/16

137 (5-3/8)

65 (2-5/8)

210 (8-1/4)

57 (2-1/4)

457 (18)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA0036A

2

2

730 (28-3/4)

724 (28-1/2)

651(25-5/8)

7/8

3/8

137 (5-3/8)

65 (2-5/8)

210 (8-1/4)

57 (2-1/4)

457 (18)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA0042A

3

2

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

7/8

3/8

137 (5-3/8)

86 (3-3/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA0048A

3

2

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

1-1/8

3/8

137 (5-3/8)

86 (3-3/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA0060A

4

1

841 (33-1/8)

946 (37-1/4)

870 (34-1/4)

1-1/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA0072A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

1-1/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA2030A

2

2

730 (28-3/4)

724 (28-1/2)

651 (25-5/8)

3/4

5/16

137 (5-3/8)

65 (2-5/8)

210 (8-1/4)

57 (2-1/4)

457 (18)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA2036A

3

1

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

1-1/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA2042A

3

1

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

1-1/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA2048A

3

1

933 (36-3/4)

829 (32-5/8)

756 (29-3/4)

1-1/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

2TWA2060A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

1-1/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

 

 

 

 

 

 

 

 

 

 

 

 

 

From Dwg. 21D153074 Rev. 5

6

18-BC51D3-2

Image 6
Contents General Location and Preparation of the UnitFT. Above UNIT-UNRESTRICTED Accutron Flow Control Valve Installing Refrigerant LinesLiquid Line Service Valve Basepan TAB RemovalService Valve Operation GAS Line Ball Service ValveGAS Line Service Valve Electrical Connections Fault IdentificationDefrost Control PIN IdentificationCompressor Start UP Operational and Checkout ProceduresTypical Field HOOK-UP Diagrams Electric Heaters2TWA Outline Drawing Models BaseMounting Hole Location Checkout Procedure Troubleshooting Chart What to Check