General Data
Accessory Description and Usage
Evaporator Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches
Rubber Isolators — 5 large rubber donuts to isolate con- densing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized.
Hard Start kit — Start capacitor and relay to assist compres- sor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc.
AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS —
(A)Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil.
AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling opera- tion.) Standard Noise Rating number is at 95°F outdoor air.