Trane 4TWB4 manual Model Nomenclature, Outdoor Units

Page 7

Model Nomenclature

Outdoor Units

4 T W B 4 0 3 6 G 1 0 0 0 A A

 

Refrigerant Type

2 = R-22

4 = R-410A

TRANE

Product Type

W = Split Heat Pump

T = Split Cooling

Product Family

Z = Leadership – Two Stage

X = Leadership

R = Replacement/Retail

B = Basic

A = Light Commercial

Family SEER

 

 

 

 

0 = 10

3 = 13

6 = 16

1 = 11

4 = 14

8 = 18

2 = 12

5 = 15

9 = 19

Split System Connections 1-6 Tons

0 = Brazed

Nominal Capacity in 000s of BTUs

Major Design Modifications

Power Supply

1 = 200-230/1/60 or 208-230/1/60

3 = 200-230/3/60

4 = 460/3/60

Secondary Function

Minor Design Modifications

Unit Parts Identifier

Air Handlers –

4 T E E 3 F 3 6 A 1 0 0 0 A A

 

Residential

 

Refrigerant Type

4 = R-410A

Application

TE = Fully Convertible

TG = Semi Convertible

TF = Front Return

Product Family

E = Leadership – Variable Speed

P = Leadership

C = Replacement/Retail

B = Basic

Flow Control

0 = No Flow Control

3 = Nonbleed TXV

Feature Identifier

0 = Standard Unit

F = Air-Tite™

Nominal Capacity in 1000’s (BTUH)

Major Design Change

Power Supply

1 = Single Phase

Electrical Connection

0 = Pig Tails

B = Circuit Breaker

D = Pull Disconnect

Future Option – Factory Installed Heater Nominal KW Value

Minor Design Modifications

Unit Parts Identifier

NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years.

Gas Furnaces

 

 

 

T U D 2 B

0

8

0

A C

V

3

2

A

 

A

Coils –

4

T

X

C

B 0 0

1

C

 

C 3

 

H

C

 

A

A

Residential

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Type

4 - R410A

Product Family

T-Premium

(Heat Pump or Convertible Coil)

Coil Design

X - Direct Expansion Evaporator Coil

Product Family

C - Cased A Coil

A - Uncased A Coil

F - Cased Horizontal Flat Coil

Coil Width (Cased/Uncased)

A - 14.5" / 13.3"

B - 17.5" / 16.3"

C - 21.0" / 19.8"

D - 24.5" / 23.3"

H - 10.5"

Refrigerant Line Coupling

0 - Brazed

Model Number Distinguisher

Major Design Change

Efficiency

C - Standard

S - Hi Efficiency (Derived from 10 SEER products)

Refrigerant Control

3 - TXV - Non-Bleed

Coil Circuitry

H - Heat Pump

Airflow Configuration

A - Upflow Only

U - Upflow / Downflow

H - Horizontal Only

C - Convertible - Upflow, Downflow, Left or Right Airflow

Minor Design Change

Unit Parts Identifier

22-1834-09

7

Image 7
Contents Split System Heat Pump Product Data Weatherguard fasteners Features and BenefitsContents General Data Product SpecificationsSound Enclosure Compressor Sump Heat Ahri Standard 210/240 Rating Conditions Outdoor Units Model NomenclatureElectrical Data Schematic Diagrams 4TWB4018, 4TWB4024, 4TWB4036Schematic Diagrams 4TWB4030 Schematic Diagrams 4TWB4042 Schematic Diagrams 4TWB4048 4TWB4049E Schematic DiagramsSchematic Diagrams 4TWB4060 4TWB4061E 4TWB4 Outline Drawing DimensionsGeneral Mechanical Specification Options