Your Meter Display

The picture below shows all the symbols that will appear on your meter display. When the meter is off, press and continue holding the or button. All segments will be displayed and remain on while holding the button down for 10 seconds. Repeat as needed to compare your meter to the display shown below.

While all characters are displayed, it is most important

to verify that is fully displayed. If there is a difference, see Error Codes and Symbols (page 17). This may affect the way you see your results.

Display Important

Top area on

Indicates beeper

 

the display

 

is turned on.

 

presenting

 

 

 

date and time.

 

 

 

.

/

Indicates

A

 

an alarm has

 

 

 

been set.

 

 

Center area on the display that shows either

Pre-meal your test result or any result marker. error codes.

or will appear if the meter is in 12 hour setup.

Displays the date format.

Results are displayed along with the preset units of measure. The 7 appears when viewing number of results over past 7 days.

Your Meter

Post-meal result marker.

Control result marker.

Indicates the meter is ready to test.

Average.

Identifies

 

a test result

Indicates it is too cold

as unique or

or too hot for your

different.

meterwwwto.BayerDiabetest accuratelys..com

Indicates the batteries are low and need to be changed.

3

Image 5
Contents User Guide Thank you for choosing the Ascensia Contour Table of Contents TestingYour Ascensia Contour Meter Important Your Testing ToolsYour Ascensia Contour Test Strip Your Ascensia Microlet Lancing DeviceYour Meter Display Your MeterYour Meter Features Important Your Meter FeaturesSymptoms of High or Low Blood Sugar Symptoms of High or Low Blood Sugar ImportantImportant Things to Know Important Important Things to KnowPotential Biohazard Before You Begin ImportantBefore You Begin Getting Ready to Test Testing Getting Ready to TestGetting Ready to Test Testing Getting the Blood Drop Testing Getting the BloodDrop Alternative Site Testing-Use the clear endcap Getting the Blood Drop TestingFor palm testing, it is For forearm testing only, rub testing area vigorouslySkin or place the blood on Top of the test strip Testing Testing Your BloodTesting Your Blood Testing Your Blood Testing To others What YOU see What IT Means What YOU should do Error Codes and SymbolsSymbols Error CodesIf you do not resolve the problem, contact Bayer Or too low Customer Service atControl Solution Testing Control Solution TestingHelp Blood glucose average or in the 7 day total Setting the Time Options Setting the Date, Time, and SoundSetting the Date, Time, and Sound Setting the Sound Setting the Date, Time, and Sound OptionsSetting the Date Setting the Month and Day format Setting the 12 or 24 Hour ClockSetting the Markers and Alarm Setting the Markers and Alarm OptionsUsing the Markers and Alarm Options Using the Markers and AlarmIf you want to mark the test result Using the Markers and Alarm OptionsIf you do not want to mark the test result Alarm Markers AlarmPre-Meal Post-MealResult is marked as a Press to view the 7 day total Using the MemoryViewing Stored Results Options Options Viewing Stored Results Changing the Batteries ExtrasCaring for the System Caring for the SystemTransferring Results to a Computer Transferring Results to a ComputerTechnical Information Technical InformationSpecifications SpecificationsWarranty Extras Service Information Service and SuppliesSupplies Replacement Parts Part NumberBayer HealthCare LLC 99B71519

CONTOUR Blood Glucose Meter and Ascensia CONTOURTM Test Strips specifications

The Bayer HealthCare CONTOUR Blood Glucose Meter, alongside Ascensia CONTOURTM Test Strips, represents a significant advancement in diabetes management technology. Designed for both ease of use and accuracy, this glucose monitoring system is tailored to meet the needs of individuals living with diabetes.

One of the main features of the CONTOUR Blood Glucose Meter is its simplicity. The device has a user-friendly interface that guides users through the testing process. With a large, easy-to-read display, results are presented clearly, enabling quick interpretation. The meter is compact and lightweight, making it convenient for on-the-go testing.

An important technological advancement in the CONTOUR Blood Glucose Meter is its advanced multi-pulse technology. This feature allows for more accurate readings by taking multiple measurements during a single test. This ensures that fluctuations in blood glucose levels are captured more effectively, delivering a precise result that the user can rely on.

The Ascensia CONTOURTM Test Strips work in tandem with the meter, utilizing a unique "No Coding" technology. This eliminates the need for coding the strips, reducing the chances of user error. The test strips are designed to require only a small blood sample, which simplifies the testing process and minimizes discomfort. Additionally, they employ a state-of-the-art biosensor technology that enhances the speed and accuracy of the readings.

Another characteristic of the CONTOUR Blood Glucose Meter is its storage capacity for test results. Users can store a significant number of previous readings, which is invaluable for tracking trends over time. This feature assists with self-management, allowing users and their healthcare professionals to make well-informed decisions based on historical data.

Furthermore, the CONTOUR system is designed to provide users with visual cues, such as color-coded ranges that indicate whether readings are within a target range. This aids in better understanding and managing blood glucose levels.

In conclusion, the Bayer HealthCare CONTOUR Blood Glucose Meter and Ascensia CONTOURTM Test Strips stand out in diabetes care with their innovative technology and user-oriented design. These features not only enhance accuracy but also empower users in their journey of managing diabetes, demonstrating a commitment to improving health outcomes.