Bayer HealthCare CONTOUR Blood Glucose Meter and Ascensia CONTOURTM Test Strips manual

Page 7

Symptoms of High or Low Blood Sugar

You can better understand your test results by being aware of the symptoms of high or low blood sugar; this will also help you decide what to do if your results seem unusual.

Some of the most common symptoms are:1

High blood sugar

Low blood sugar

(Hyperglycemia):

(Hypoglycemia):

frequent urination

shakiness

excessive thirst

sweating

blurred vision

fast heartbeat

increased fatigue

blurred vision

extreme hunger

strange behavior

irritability

confusion

 

 

passing out

Ketones (Ketoacidosis) from

seizure

 

 

untreated Hyperglycemia:

shortness of breath

nausea and vomiting

very dry mouth

If you are experiencing any symptoms, test your blood glucose. If your test result is below 50 mg/dL or above 250 mg/dL, contact your doctor immediately.

For additional information and symptoms, contact a healthcare professional or refer to the website for the American Diabetes Association: www.diabetes.org

Symptoms of High or Low Blood Sugar Important

www.BayerDiabetes.com5

Image 7
Contents User Guide Thank you for choosing the Ascensia Contour Table of Contents TestingYour Ascensia Microlet Lancing Device Important Your Testing ToolsYour Ascensia Contour Meter Your Ascensia Contour Test StripYour Meter Display Your MeterYour Meter Features Important Your Meter FeaturesSymptoms of High or Low Blood Sugar Symptoms of High or Low Blood Sugar ImportantImportant Things to Know Important Important Things to KnowBefore You Begin Before You Begin ImportantPotential Biohazard Getting Ready to Test Testing Getting Ready to TestGetting Ready to Test Testing Drop Testing Getting the BloodGetting the Blood Drop For forearm testing only, rub testing area vigorously Getting the Blood Drop TestingAlternative Site Testing-Use the clear endcap For palm testing, it isTesting Your Blood Testing Testing Your BloodSkin or place the blood on Top of the test strip Testing Your Blood Testing To others What YOU see What IT Means What YOU should do Error Codes and SymbolsIf you do not resolve the problem, contact Bayer Error CodesSymbols Or too low Customer Service atControl Solution Testing Control Solution TestingHelp Blood glucose average or in the 7 day total Setting the Date, Time, and Sound Options Setting the Date, Time, and SoundSetting the Time Setting the Date Setting the Date, Time, and Sound OptionsSetting the Sound Setting the Month and Day format Setting the 12 or 24 Hour ClockSetting the Markers and Alarm Setting the Markers and Alarm OptionsUsing the Markers and Alarm Options Using the Markers and AlarmIf you do not want to mark the test result Using the Markers and Alarm OptionsIf you want to mark the test result Alarm Post-Meal AlarmMarkers Pre-MealResult is marked as a Viewing Stored Results Options Using the MemoryPress to view the 7 day total Options Viewing Stored Results Changing the Batteries ExtrasCaring for the System Caring for the SystemTransferring Results to a Computer Transferring Results to a ComputerTechnical Information Technical InformationSpecifications SpecificationsWarranty Extras Service Information Service and SuppliesSupplies Replacement Parts Part NumberBayer HealthCare LLC 99B71519

CONTOUR Blood Glucose Meter and Ascensia CONTOURTM Test Strips specifications

The Bayer HealthCare CONTOUR Blood Glucose Meter, alongside Ascensia CONTOURTM Test Strips, represents a significant advancement in diabetes management technology. Designed for both ease of use and accuracy, this glucose monitoring system is tailored to meet the needs of individuals living with diabetes.

One of the main features of the CONTOUR Blood Glucose Meter is its simplicity. The device has a user-friendly interface that guides users through the testing process. With a large, easy-to-read display, results are presented clearly, enabling quick interpretation. The meter is compact and lightweight, making it convenient for on-the-go testing.

An important technological advancement in the CONTOUR Blood Glucose Meter is its advanced multi-pulse technology. This feature allows for more accurate readings by taking multiple measurements during a single test. This ensures that fluctuations in blood glucose levels are captured more effectively, delivering a precise result that the user can rely on.

The Ascensia CONTOURTM Test Strips work in tandem with the meter, utilizing a unique "No Coding" technology. This eliminates the need for coding the strips, reducing the chances of user error. The test strips are designed to require only a small blood sample, which simplifies the testing process and minimizes discomfort. Additionally, they employ a state-of-the-art biosensor technology that enhances the speed and accuracy of the readings.

Another characteristic of the CONTOUR Blood Glucose Meter is its storage capacity for test results. Users can store a significant number of previous readings, which is invaluable for tracking trends over time. This feature assists with self-management, allowing users and their healthcare professionals to make well-informed decisions based on historical data.

Furthermore, the CONTOUR system is designed to provide users with visual cues, such as color-coded ranges that indicate whether readings are within a target range. This aids in better understanding and managing blood glucose levels.

In conclusion, the Bayer HealthCare CONTOUR Blood Glucose Meter and Ascensia CONTOURTM Test Strips stand out in diabetes care with their innovative technology and user-oriented design. These features not only enhance accuracy but also empower users in their journey of managing diabetes, demonstrating a commitment to improving health outcomes.