Oregon Scientific EMR812HGN user manual Maximum and Minimum Temperature and Humidity

Page 7

To deactivate the remote-sensor scanning mode:

Press any button.

MAXIMUM AND MINIMUM

TEMPERATURE AND HUMIDITY

The maximum and minimum recorded temperature and humidity readings will automatically be stored in the memory.

To display the maximum and minimum display memory:

1.Select the channel to be checked.

2.Press MEM/CLEAR once to display the maximum temperature and again the minimum temperature. The respective indicators, MAX or MIN will be displayed.

To clear the memory:

• Press and hold MEM/CLEAR for 2-seconds.

If you press MEM/CLEAR now, the maximum and minimum temperatures will have the same values as the current ones until different readings are recorded.

EN

HOW TO USE CHANNEL-1

TEMPERATURE/HUMIDITY ALARM

Upper and lower temperature and humidity limits for channel-1 can be set so that an alarm activates when the limits are exceeded.

The high and low temperature and humidity displays are selected by sequentially pressing HI/LO.

The high-low displays are as follows:

Sequence

Respective Display

Pressing HI/LO once

Enters HI temperature display

 

 

Pressing HI/LO twice

Enters HI humidity display

 

 

Pressing HI/LO three times

Enters LO temperature display

 

 

Pressing HI/LO a four time

Enters LO humidity display

 

 

To set a high or low temperature or humidity alarm:

1.Press HI/LO, channel-1 will be displayed.

2.Press to set the temperature or humidity limit. Each press will increase increments by one degree or percentage. Press and hold the button for a rapid-scrolling sequence by increments of five.

7

Image 7
Contents Introduction Features Main UnitFeatures Remote THERMO-HYGRO Sensor Removable table stand Battery and Channel Installation Remote UnitBefore YOU Begin Wall-mount holderFollow these steps to install / replace batteries Battery Installation Main UnitGetting Started HOW to Check Remote Indoors TemperaturesHOW to Read KINETIC-WAVE Display To force a signal searchCOMFORT-LEVEL Icons Temperature and Humidity Trend IndicatorsRemote Sensor Scanning HOW to USE CHANNEL-1 TEMPERATURE/HUMIDITY Alarm Maximum and Minimum Temperature and HumidityIf that fails, check Disconnected SignalsTo disable an alarm To disable a sounding alarmHOW to USE the Table Stand or Wall Mounting LOW Battery WarningTransmission Collision Precautions Reset ButtonSpecifications Power Additional information About Oregon Scientific EC-DECLARATION of Conformity