Barco MGD 2621 user manual Word about the memory system, To exit the menu system

Page 16

A word about the memory system

To exit the menu system:

1Turn the Contrast knob until the Save Changes dialog appears in the OSD:

2Turn the Brightness knob to toggle between Yes and No. Select Yes to save the changes, select No to exit without saving the changes.

3Turn the Contrast knob to exit.

See also: Menu Exit, later in this chapter.

As explained in the introduction of this manual, the memory of the display can hold four different scanning formats. Each scanning format is characterized by the following parameters: Horizontal sync. frequency, horizontal sync. polarity, vertical sync. frequency, and vertical sync. polarity.

If the parameters of the connected signal are the same of the parameters of one of the scanning formats in memory, the automatic scanning system selects this scanning mode. This means the image on the display adapts to all the adjustment values stored in this scanning mode.

In case the connected sync signal doesn't match one of the stored scanning modes, the automatic scanning system selects the nearest scanning mode. This means the scanning mode of which the stored sync frequencies are as close as possible to the sync frequencies of the connected signal.

When you change one or more adjustment values, and you decide to save the changes upon exit of the menu system, the changed values are stored in the actually selected scanning mode. This means the actually selected scanning mode is overwritten by the new adjustment values.

Advanced Adjustments

16

Image 16
Contents MGD 2621 P Medical Greyscale Display Page Safety Instructions Contents Introduction OverviewCalibration and adjustments Power saving system About the manualsInstallation Precautions Package contentsUnpacking the display Power connection Connectors Location of controlsConnection of video signals Connection of data signals Connection of an optical sensor Important considerations How to switch on the display Operation User ControlsAdvised setting for contrast and brightness How to use LUCAdvanced Adjustments for Service Staff only On-screen menu systemWord about the memory system To exit the menu systemFocus Geometry Info SH Comp. Top SH Comp. BottomLight Luma equalizing Miscellaneous Mode selection Menu exit Picture tube MaintenanceCabinet Troubleshooting On the picture tube appears the message No Valid Sync SignalAppendix a Background Information Clamping Luminance Uniformity CorrectionBe thicker in the center Appendix B Technical Specifications Picture tubeMGD 2621 P Users Guide B410030/Rev February

MGD 2621 specifications

The Barco MGD 2621 is a high-performance medical display solution engineered to meet the rigorous demands of healthcare environments. This advanced monitor is part of Barco's commitment to enhancing clinical workflow, ensuring precise diagnosis, and elevating patient care through superior imaging technology.

One of the standout features of the MGD 2621 is its remarkable display clarity. With a resolution of 2560 x 1600 pixels, this display provides stunning image detail, crucial for diagnostic processes that depend on the visibility of minute anatomical structures. The high pixel density ensures that images are crisp and clear, resulting in accurate assessments by medical professionals.

Color accuracy is another hallmark of the Barco MGD 2621. The monitor boasts a wide color gamut, facilitating true-to-life color reproduction. This feature is particularly vital in areas such as radiology and pathology, where distinguishing between subtle color differences can influence diagnosis and treatment plans.

The Barco MGD 2621 utilizes advanced DICOM conformance to faithfully reproduce medical images with consistent luminance and contrast. This adherence to DICOM standards ensures that images meet the required specifications for clinical use, facilitating reliable comparisons and evaluations.

In terms of ergonomics, the MGD 2621 is designed for optimal usability in fast-paced environments. It features flexible mounting options that allow healthcare professionals to position the monitor at heights and angles that best suit their needs. Additionally, the monitor's anti-glare glass front provides enhanced visibility under various lighting conditions, further improving the user experience.

Barco has integrated its proprietary calibration technology into the MGD 2621, ensuring that the display maintains consistent performance over time. Automatic calibration and built-in quality assurance features provide peace of mind for users, knowing that images will retain their integrity throughout their use.

Furthermore, connectivity is seamlessly addressed in the Barco MGD 2621. The monitor supports various input formats, including dual-link DVI and DisplayPort, ensuring compatibility with a wide range of imaging systems. This versatility allows for an efficient integration into existing medical infrastructure.

In summary, the Barco MGD 2621 is an exemplary choice for medical professionals requiring a reliable, high-quality display solution. Its combination of superior image clarity, color accuracy, ergonomic design, and robust connectivity makes it a pivotal tool in the pursuit of excellence in medical imaging and patient care. Healthcare institutions investing in the MGD 2621 are not just enhancing their diagnostic capabilities but are also committing to providing the highest quality of care for their patients.