The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening.

1.Position the whirlpool into the installation opening and level the deck in both directions, shimming the integral leveling feet IF necessary. Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).

2.Remove the whirlpool and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line.

!The rim of the bath must not support weight.

3.Install drain components to the whirlpool following the drain installation instructions. Before replacing your whirlpool for final installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing and Table 1 for suggested opening size (shadowed) and location dimensions. The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout in the floor.

The floor structure beneath the bath must be able to support a total weight of bath,

!

water, and bather. Refer to Table 1 under total weight for your model.

The bath must be supported along its entire bottom. Use mortar as bedding material (do not use sand or foam). Apply enough mortar to support the complete bottom of the bath. After the mortar has been poured, and before it sets, position whirlpool or bath within recess until the rim is leveled against the leveling stringers (see "Typical Recess Installation") shown below.

!The rim of the bath must not support weight. Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must be self-supporting if it contacts the deck of the bath.

FIGURE 1

TYPICAL INSTALLATION

C*

SEE TABLE 1 ON PAGE 7.

 

TILE

 

WALLBOARD

TILE

SEALANT

BATH

BEAD

 

STRIP

 

 

ADHESIVE

LEVELING STRINGER 1 x 4 (not for support)

NOTE: Tile bead kit not included and must be purchased separately.

TYPICAL RECESS INSTALLATION

TYPICAL PIER TYPE INSTALLATION

AS DESIRED

F

CUTOUT

C

G CUTOUT

C

E

NOTE:

FRONT EDGE

OF BATH MUST BE SUPPORTED BY STUD WALL OR ELJER APRON KIT

D

12

W

(305 mm)

LEVELING

 

STRINGERS

24

 

(610 mm)

ACCESS PANEL MUST BE LOCATED

ON THE SAME SIDE AS THE MOTOR.

ALLOW OPEN FRAMING ON

PUMP/MOTOR END FOR SERVICE.

ACCESS PANELS NOT REQUIRED

FOR BATH TUBS.

AS DESIRED

MOUNTING

SURFACE

WATERPROOF SEALANT

BATH

12

(305 mm)

24

(610 mm)

ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR.

ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE.

ACCESS PANELS NOT REQUIRED

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 7.

FOR BATH TUBS.

UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)

IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.

FOR C, G & F DIMENSIONS SEE TABLE 1 ON PAGE 7.

5

754764-100 Rev. A

Image 5
Contents Premiere Whirlpool Installation Table of Contents Important Safety Instructions Installation and Framing Instructions Installation and Framing Instructions Typical Flange Mounting Detail Suggested Whirlpool / Bath Installation MethodGeneral Specifications for Eljer Whirlpools and Bath Tubs SpecificationsMadison Model ROUGH-IN ReferencesCypress Model Triangle Model Canterbury ModelPatriot Model 015-0309/0305 ROUGH-IN References Emblem Model Emblem Total Massage ModelElectrical Diagram Read and Follow ALL Instructions Total Massage Circuit with Optional Heater Control PAD Pump Flow Variable Timer Valve Blower HeaterTotal Massage Whirlpools AMP GfciOperating Instructions Do not wax surfaces where you walk or stand Cleaning and MaintenanceCanada