Schneider Electric 9070 manual R11A R11B

Page 47

Industrial Control Transformers

Field Installed Fuse Options

3.13

1.62

2.10

R11A

3.21

1.98

2.07

R11B

47

08/2005

 

 

 

© 1999–2005 Schneider Electric All Rights Reserved

Image 47
Contents Industrial Control Transformers Page Product Description Product DescriptionType T VA Ratings Type T TransformersType T Transformers CE Marking95% 90% 85% Regulation Chart for Type TSelection Guide Secondary VoltageSource Load Voltage Go To Codes Pages Type T Transformers for 120 Volt LoadsSingle Dual Custom-Built Type T TransformersType T Transformers for 24 Volt Loads One Primary Tap Two Primary TapsVoltages DimensionsVolt Control Secondary Voltage and Connection OptionsVoltages Connections Key Type T MultiTap TransformersCatalog Acc Slots Number1 ConnectionsVoltage Voltages Connections Volt SecondaryPrimary Secondary UniversalCatalog Type T Transformers with Dual Secondary120/240 Volt Secondary Voltage VoltagesCatalog Acc Slots Number1 Key Catalog Acc Type T Transformers with 24 Volt SecondaryNumber1 Key 9070T50D19 Type T Units with Dual 12/24 Volt Secondary Amps Multiple SecondaryMultiple Secondary Only Type T Units with Dual 24/120 Volt Secondary Tapped Units120 Acc 115Slots Only Catalog 115V 24V9070T50D114 B D a B 150 Exceed Primary Max 200 9070T200t 120 114 Load Type T Performance Data0PF 100% 75% 50% 25% 60HZ 50HZ WattsType T Special Quote Request Sheet Type EO VA Ratings Regulation Chart for Type EOType EO Transformers Type EO TransformersType EO Transformers for 24 Volt Loads Type EO Transformers for 120 Volt LoadsCatalog Slots Number Voltage Voltages Catalog Slots Number19070EO17 t Voltages Connections Inrush x FL RMS Type EO Performance DataCatalog Core Coil FL Total Reg Eff BTU/hr 0PF 100% 75% 50% 25% 60HZClass 9070 Type EL, KL Transformers with LeadsTransformers with Leads Fuse Protection Matrix for Choosing Proper Fuse ConfigurationFuse Protection H3 H2 X2X1 H1H4 H1H4 H3 H2 Fuse Protection Options Description of Accessory KeysFingersafe Covers not supplied with unit AccessoriesClass Type VA Accessory Key Description VA Accessory KeyVolts Primary Fusing to Meet NECVolts Volts Secondary Fuse Rating Primary Fusing to Meet CESecondary Fusing to Meet NEC and CE Recommended Fuse Sizes for the Secondary to Meet NEC and CEVolt Control Secondary-Primary and Secondary Fuse Block Type TF Transformers9070TF25D20 Primary Fusing Field Installed Fuse OptionsField Installed Fuse Options R01A R01B Primary and Secondary Fusing R11A R11B R12A R12B Secondary Fusing S22A S22B SF25A SF25B AP1 AP2 Secondary Fuse Clips Jumper Fuse ClipTerminal Blocks Example of Series and Parallel Connections ApplicationApplication Example of a typical application SolutionTechnical Data Question Answer Frequently Asked QuestionsFrequently Asked Questions Selecting a 9070 Type T control transformer? Schneider Electric USA