Schneider Electric 9070 manual Type T Units with Dual 12/24 Volt Secondary

Page 18

Industrial Control Transformers

Type T Transformers with 24 Volt Secondary

Type T Units with Dual 12/24 Volt Secondary

Voltage and Connection Options

Voltage

Voltages

 

Connections

 

 

 

 

 

Code

Primary

Secondary

 

Primary

 

Secondary

 

 

 

 

 

 

 

 

 

 

 

D13

120

 

Connect to H1 and H2

 

 

 

 

 

 

D36

600

 

Connect to H1 and H2

 

 

H1

 

 

H2

 

 

 

 

 

 

 

 

 

 

120:

Connect to H1 and H4

 

 

 

 

 

 

 

 

 

 

Jumper H1 with H3

12:

Connect to X1 and X4

X4

X2

X3

X1

D54

120 x 240

 

 

Jumper H2 with H4

 

 

 

Jumper X1 with X3

 

 

 

 

 

 

12/24

240:

Connect to H1 and H4

 

Jumper X2 with X4

 

 

 

 

 

 

 

 

Jumper H2 with H3

24:

Connect to X1 and X4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240:

Connect to H1 and H4

 

Jumper X2 with X3

H1

H3

H2

H4

 

 

 

 

Jumper H1 with H3

 

 

 

 

 

 

D59

240 x 480

 

 

Jumper H2 with H4

 

 

 

 

 

 

 

 

 

480:

Connect to H1 and H4

 

 

X4

X2

X3

X1

 

 

 

 

Jumper H2 with H3

 

 

 

 

 

 

Dimensions

 

VA

Catalog

Fig.

Acc.

 

A

 

B

 

C

E

 

F

 

Slots

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UL

 

CE

Number1

Key

IN

 

mm

IN

 

mm

IN

 

mm

IN

 

mm

IN

 

mm

IN

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

25

9070T25t

1

I

3.09

 

79

3.00

 

76

2.58

 

66

2.00

 

51

2.50

 

64

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

50

9070T50t

1

I

3.09

 

79

3.00

 

76

2.58

 

66

2.00

 

51

2.50

 

64

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

75

9070T75t

1

I

3.34

 

85

3.38

 

86

2.89

 

73

2.38

 

61

2.81

 

71

0.20 x 0.48

 

5 x 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

100

9070T100t

1

I

3.34

 

85

3.38

 

86

2.89

 

73

2.38

 

61

2.81

 

71

0.20 x 0.48

 

5 x 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

150

9070T150t

1

I

3.59

 

91

3.75

 

95

3.20

 

81

2.88

 

73

3.13

 

80

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

200

9070T200t

1

I

3.59

 

91

3.75

 

95

3.20

 

81

2.88

 

73

3.13

 

80

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

 

160

9070T250t

2

I

5.30

 

135

3.75

 

95

3.21

 

82

2.88

 

73

3.13

 

80

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

200

9070T300t

2

I

4.74

 

120

4.50

 

114

3.84

 

98

2.56

 

65

3.75

 

95

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350

 

250

9070T350t

2

I

5.11

 

130

4.50

 

114

3.84

 

98

3.00

 

76

3.75

 

95

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

300

9070T500t

2

I

5.49

 

139

4.50

 

114

3.84

 

98

3.56

 

90

3.75

 

95

0.20 x 0.38

 

5 x 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Complete the catalog number by replacing the t with the correct Voltage Code from the “Voltage and Connection Options” table above.

D

B

D A

A

 

 

 

 

 

C

F

E

F

 

 

Figure 1

 

Figure 2

B

C

E

18

© 1999–2005 Schneider Electric All Rights Reserved

 

 

 

08/2005

Image 18
Contents Industrial Control Transformers Page Product Description Product DescriptionCE Marking Type T TransformersType T Transformers Type T VA RatingsSecondary Voltage Regulation Chart for Type TSelection Guide 95% 90% 85%Type T Transformers for 120 Volt Loads Source Load Voltage Go To Codes PagesOne Primary Tap Two Primary Taps Custom-Built Type T TransformersType T Transformers for 24 Volt Loads Single DualVoltage and Connection Options DimensionsVolt Control Secondary VoltagesVoltages Connections Connections Type T MultiTap TransformersCatalog Acc Slots Number1 KeyVolt Secondary Voltage Voltages ConnectionsUniversal Primary SecondaryVoltage Voltages Type T Transformers with Dual Secondary120/240 Volt Secondary CatalogCatalog Acc Slots Number1 Key Type T Transformers with 24 Volt Secondary Catalog AccNumber1 Key 9070T50D19 Type T Units with Dual 12/24 Volt Secondary Multiple Secondary Multiple SecondaryAmps Type T Units with Dual 24/120 Volt Secondary Tapped Units 120Only 115V 24V 115Slots Only Catalog Acc9070T50D114 B D a B 150 Exceed Primary Max 200 9070T200t 120 114 Watts Type T Performance Data0PF 100% 75% 50% 25% 60HZ 50HZ LoadType T Special Quote Request Sheet Type EO Transformers Regulation Chart for Type EOType EO Transformers Type EO VA RatingsType EO Transformers for 120 Volt Loads Type EO Transformers for 24 Volt LoadsCatalog Slots Number Catalog Slots Number1 Voltage Voltages9070EO17 t Voltages Connections 0PF 100% 75% 50% 25% 60HZ Type EO Performance DataCatalog Core Coil FL Total Reg Eff BTU/hr Inrush x FL RMSTransformers with Leads Transformers with LeadsClass 9070 Type EL, KL Matrix for Choosing Proper Fuse Configuration Fuse ProtectionFuse Protection H3 H2 X2X1 H1H4 H1H4 H3 H2 Description of Accessory Keys Fuse Protection OptionsVA Accessory Key AccessoriesClass Type VA Accessory Key Description Fingersafe Covers not supplied with unitPrimary Fusing to Meet NEC VoltsVolts Recommended Fuse Sizes for the Secondary to Meet NEC and CE Primary Fusing to Meet CESecondary Fusing to Meet NEC and CE Volts Secondary Fuse RatingType TF Transformers Volt Control Secondary-Primary and Secondary Fuse Block9070TF25D20 Field Installed Fuse Options Field Installed Fuse OptionsPrimary Fusing R01A R01B Primary and Secondary Fusing R11A R11B R12A R12B Secondary Fusing S22A S22B SF25A SF25B AP1 AP2 Jumper Fuse Clip Secondary Fuse ClipsTerminal Blocks Application ApplicationExample of Series and Parallel Connections Solution Example of a typical applicationTechnical Data Frequently Asked Questions Frequently Asked QuestionsQuestion Answer Selecting a 9070 Type T control transformer? Schneider Electric USA