Lifescan Basic Blood Glucose Monitoring System manual Usa

Page 98

The system described herein is covered by one or more of the following U.S. patents: D417,504, D428,150, 5,059,394, 5,187,100, 5,843,692, 5,968,760, 6,045,567, 6,156,051, 6,197,040 and 6,489,133. Use of the monitoring device described herein is protected under the following U.S. patents: 4,935,346, 5,049,487, 5,179,005, and 6,268,162. Purchase of the monitoring device described herein does not act to grant a use license under these patents. Such a license is granted only when the device is used with OneTouch® Test Strips, or with test strips manufactured by Diagnostic Solutions, Inc. No test strip supplier other than LifeScan, Inc. is authorized to grant such a license. The accuracy of results generated with LifeScan meters using test strips manufactured by anyone other than LifeScan has not been evaluated by LifeScan.

OneTouch® is a trademark of LifeScan, Inc.

©2003 LifeScan, Inc. Milpitas, CA 95035. 10/03 AW 063-318-01A

AW 06331801A

El folleto para el propietario del OneTouch® Basic® se encuentra disponible en español. Para recibir su copia gratuita, favor de llamar al número gratis 1 800 381-7226.

The OneTouch® Basic® instructional materials are available in Spanish. To receive your free copy, please call toll-free 1 800 381-7226.

LifeScan Customer Services 24-Hour,

Toll-Free Assistance:

USA

(English): 1 800 227-8862

USA

(Español): 1 800 381-7226

Visit the LifeScan Web site at:

www.LifeScan.com

Image 98
Contents Basic Page Page Important The OneTouch Basic System kit contains Table of Contents Testing Your Blood Page Page Introduction Precautions Limitations Infection Control Getting Started OneTouch Basic Blood GlucoseComplete OneTouch Basic Blood Glucose Monitoring System OneTouch Basic Blood Glucose Meter Basic MeterTest Strip HOLDER. The test strip OneTouch Basic, Profile, OneTouch II Test Strips Test StripImportant Test Strip Information OneTouch Normal Control Solution To practice the test procedure,Code the OneTouch Basic Meter in these three easy steps Before TestingSetting Meter Code Press the On/Off Button Match the Code NumbersChecking the System Code the MeterChecking with the Check Strip How to do a check strip test Page Example Checking with Control Solution Spot with the tip of the vial Do a control solution testControl solution test tips Important Control Solution Test Information Spot facing up How to do a control solution testPress On/Off Button. Insert Test Strip Test strip in allApply Control Solution Control range You are ready to test your bloodControl solution results Meter malfunction Extremes in testing temperatures Testing Your Blood Abbreviated Test ProcedureDetailed Test Procedure TestGetting a Drop of Blood While the lancet is in the OneTouch Penlet Plus Sampler, twist off the proAdjust the puncture depth setting Cock the OneTouch Penlet Plus SamplerWash Your Hands Lance Your FingerYour blood glucose test Clockwise Required blood volume. Proceed withRemove the Lancet Always use caution when removing How to Test Your Blood Replace the vial Cap immediately Do not touch Test spot on Remove a testStrip from the vial Test strip. The testApply Blood Sample Drop Be sure that youTouch only the tip Blood to the testResults will appear without time Date. See Accurate Results SecondsAfter the result is displayed Special Messages Checking the Amount of Blood on the Test Strip Strip from If the following messageRemove the test Back Comparing Meter and Laboratory Results Take your meter with you to the labComparing the results ExamplePage Using the Meter Memory Entering the Memory ModeRecalling Test Results Setting Meter Options Entering and Using Set-Up ModeIf you want to change an option setting, use the C button Clock option is set to and when it is set to Clock Time and DateSetting the Time Setting the Date Beep Prompts Or press the M button to move to the next optionLanguage Time Format Date FormatUnit of Measure Decimal SeparatorExiting the Set-Up Mode Itself off after two minutes of no activitySolving Problems Test Procedure MessagesSolution test Button108 mg/dL Mmol/L100 mg/dL 80 mg/dLHi mg/dL 58 mg/dLAlternating with 58 mg/dL Alternating withError Messages When this symbol is flashing, the batteries are too low BattryMeter was used in very bright light Correctly New test strip Test strip moved duringTest New test strip Test strip was not inserted 800 Error3 retest Not enough blood retest Your meter on, your meter’s If appearing when you turnWas turned on Test area may be dirtyRepeat the test with a Last test failed after the countdown started Strip vial to operate Message when the meterMeter requires a test Has not yet been codedKeep the test strip holder and test area clean see Taking Care Your MeterAppears on the display Cleaning the MeterDoing a Daily Check Remove the Test Strip Holder from the Meter Clean the Test Strip Holder Wash only the test strip holder withMay also be used. Do not apply full Careful not to scratch the test areaReplace the Test Strip Holder Replacing the Batteries Batteries should last aboutTo replace the batteries Against a hard surface Remove the battery compartmentDoor References Remove the batteries and reinsert them as illustratedAlkaline batteries SpecificationsDimensions 4.3 2.6 Weight 4.1 ounces with batteries 15-35CThree-Year Warranty Guarantee WarrantyDay Money-Back Guarantee Page Index OneTouch Penlet Plus Adjustable Blood Page Page Page USA