Oregon Scientific TP391 Roger Beep, N086L004722-016 REV.1 page 14/152, LCD Symbol Description

Page 14

To change the VOX level:

1.Press 4 times until the number starts flashing.

2.Press and hold or to change the VOX level.

3. Press

to confirm and exit the menu. Or, press

to

confirm and go to the next Menu Option.

 

LCD SYMBOL

DESCRIPTION

 

0VOX disabled

3Low sensitivity – only audibly loud voices are transmitted (useful for noisy environments)

2Normal sensitivity – ideal setting for voice-activated transmission

1High sensitivity – detects and transmits all sounds (including background noise)

Once the VOX level is activated you can set a delay time, which keeps the unit transmitting for 1 to 5 seconds after you have finished speaking (level 1 = 1 second and level 5 = 5 seconds).

To set the delay time:

1.Press 5 times until the number starts flashing.

2.Follow steps 2-3 above.

Roger Beep

With Roger Beep, the receiving party hears a beep tone when a message has been transmitted. This avoids situations where messages are interrupted during transmission.

To disable / enable Roger Beep:

Press and hold , then press to turn ON the unit.

EN

12

P/N:086L004722-016 REV.1 PAGE: 14/152

Image 14
Contents Model TP391 N086L004722-016 REV.1 page 1/152Contents Pair of PMR446 TWO WAY Personal Radios Model TP391Front view N086L004722-016 REV.1 PAGE 3/152N086L004722-016 REV.1 PAGE 4/152 Description FunctionBack View N086L004722-016 REV.1 page 5/152N086L004722-016 REV.1 PAGE 6/152 Lcd display symbolsSymbol Function Safety and Care Instructions N086L004722-016 REV.1 PAGE 7/152N086L004722-016 REV.1 PAGE 8/152 PowerGetting Started To insert the batteriesN086L004722-016 REV.1 PAGE 9/152 To charge the battery using the AC adapterTurn the unit on / OFF To turn the unit on or OFFTalk to another transceiver VolumeReset Another transceiverKeypad lock Symbol Setting DescriptionMenu Options N086L004722-016 REV.1 page 11/152To select between 8 channels or 38 Ctcss codes Select a channel or CtcssN086L004722-016 REV.1 page 12/152 Call tone VOX level / voice delay timeTo set up a headset N086L004722-016 REV.1 page 13/152N086L004722-016 REV.1 page 14/152 LCD Symbol DescriptionRoger Beep N086L004722-016 REV.1 page 15/152 Scan for a Channel / CtcssDual Watch DW Problem Possible Causes / Remedies ResetTroubleshooting N086L004722-016 REV.1 page 16/152N086L004722-016 REV.1 page 17/152 SpecificationsWeight without batteries Grams 2.5 oz About Oregon Scientific EU-DECLARATION of Conformity N086L004722-016 REV.1 page 18/152