Teledex AC9205S, AC8205S manual To Place a Call on Hold, To Remove a Call From Hold

Page 3

Using the Hold Key

The HOLD key places the call on hold locally at the cordless telephone.

To Place a Call on Hold:

1.With a call active, press the red HOLD key on either the handset or base unit.

2.The red line LED will slowly blink, indicating the call is on hold.

3.If a conference call is active, pressing HOLD will place all connections on hold.

To Remove a Call From Hold:

1.Press the line key of the call on hold, or the HOLD key again. This will remove the call from hold, making the call active again.

2.The red line LED will return to steady illumination, indicating the line is active.

3.During a conference call, to remove both lines from hold, press the CONF key.

To Change Phones After Placing a Call on Hold:

1.Place the call on hold as above.

2.Pick up the call at another telephone that is on the same line. The telephone will activate the line and remove the hold at the original telephone.

To Mute the Speakerphone

1.Press the MUTE key on the base unit. The red LED above the MUTE key will illuminate. The party on the other end will not be able to hear you when the MUTE LED is lit.

2.Press the MUTE key again to turn off the mute feature. The MUTE LED will go out.

Converting From Desk to Wall Mount

The AC8200/AC9200 series can be adapted for wall mounting applications. The conversion is easiest to make when the handset and cords are not connected.

1.Located on the handset cradle, above the speaker grill, is the wall/desk mount clip. Remove this clip by firmly pushing it upward towards the top of the phone.

2.Flip the clip over (top to bottom) so that the protruding edge is towards the top of the phone and replace it in its slot.This edge will hold the handset when the phone is mounted on the wall.

3.Turn the telephone over so the bottom is up, facing you. Place it on a non-abrasive surface to prevent scratching.

4.Locate and remove the mounting bracket. Firmly push back and pull up to remove two of the four retaining tabs.

5.Rotate the mounting bracket 180º degrees clockwise, so that the mounting eyelet on the bracket is facing in the same direction as the other mounting eyelet located on the bottom of the telephone.

6.Insert the top two retaining tabs of the mounting brackets into the mounting bracket slots (located near the middle of the telephone). Then firmly push down to insert

the retaining tabs on the opposite side of the mounting bracket.

7.Connect a 15-foot RJ-45 cord into the LINE jack on the back of the phone.

8.Turn the telephone over, and slide the telephone down onto the mounting posts of the wall bracket. Ensure that both eyelets line up with the mounting posts.

The Ringer Equivalence Number (REN) of this device is 0.7B. Notice: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. This telephone connects to the telephone network under the connecting arrangement code CA11A.

IMPORTANT SAFETY INSTRUCTIONS

WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:

1.READ AND UNDERSTAND ALL INSTRUCTIONS.

2.FOLLOW ALL WARNINGS AND INSTRUCTIONS MARKED ON THE PRODUCT.

3.UNPLUG THE PRODUCT FROM THE WALL OUTLET BEFORE CLEANING. DO NOT USE LIQUID CLEANER OR AEROSOL CLEANERS. USE A DAMP CLOTH FOR CLEANING.

4.DO NOT USE THIS PRODUCT NEAR WATER, FOR EXAMPLE, NEAR A BATHTUB, WASH BOWL, KITCHEN SINK OR LAUNDRY TUB, IN A WET BASEMENT, OR NEAR A SWIMMING POOL.

5.DO NOT PLACE THIS PRODUCT ON AN UNSTABLE CART, STAND OR TABLE. THE PRODUCT MAY FALL, CAUSING SERIOUS DAMAGE TO THE PRODUCT.

6.SLOTS AND OPENINGS IN THE CABINET AND THE BACK OF BOTTOM ARE PROVIDED FOR VENTILATION, TO PROTECT IT FROM OVERHEATING. THESE OPENINGS MUST NOT BE BLOCKED OR COVERED. THE OPENINGS SHOULD NEVER BE BLOCKED BY PLACING THE PRODUCT ON THE BED, SOFA, RUG OR ANY OTHER SIMILAR SURFACE. THIS PRODUCT SHOULD NEVER BE PLACED NEAR OR OVER A RADIATOR OR HEAT REGISTER. THIS PRODUCT SHOULD NOT BE PLACED IN A BUILT-IN INSTALLATION UNLESS PROPER VENTILATION IS PROVIDED.

7.NEVER PUSH OBJECTS OF ANY KIND INTO THIS PRODUC THROUGH CABINET SLOTS AS THEY MAY TOUCH DANGEROUS VOLTAGE POINTS OR SHORT OUT PARTS THAT COULD RESULT IN A RISK OF FIRE OR ELECTRIC SHOCK. NEVER SPILL LIQUID OF ANY KIND ON THE PRODUCT.

8.TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT DISASSEMBLE THIS PRODUCT. BUT TAKE IT TO A QUALIFIED SERVICE FACILITY IF SERVICE OR REPAIR WORK IS REQUIRED. OPENING OR REMOVING COVERS MAY EXPOSE YOU TO DANGEROUS VOLTAGES OR OTHER RISKS. INCORRECT REASSEMBLY CAN CAUSE ELECTRIC SHOCK WHEN THE APPLIANCE IS SUBSEQUENTLY USED.

9.UNPLUG THIS PRODUCT FROM THE WALL OUTLET AND REFER SERVICING TO QUALIFIED SERVICE PERSONNEL UNDER THE FOLLOWING CONDITIONS:

-WHEN THE POWER SUPPLY CORD OR PLUG IS DAMAGED OR FRAYED.

-IF LIQUID HAS BEEN SPILLED INTO THE PRODUCT.

-IF THE PRODUCT HAS BEEN EXPOSED TO RAIN OR WATER.

-IF THE PRODUCT DOES NOT OPERATE NORMALLY BY FOLLOWING THE OPERATING INSTRUCTIONS. ADJUST ONLY THOSE CONTROLS THAT ARE COVERED BY THE OPERATING INSTRUCTIONS, AS IMPROPER ADJUSTMENT OF OTHER CONTROLS MAY RESULT IN DAMAGE,AND MAY REQUIRE

Image 3
Contents Battery Safety Instructions Handset/Base Registration ProcedureCharging the Battery Cleaning the Battery ContactsUsing the handset To assign a ring tone to a line crescendo ring modeTo return to regular ring mode To answer a call using the speakerphoneTo Place a Call on Hold To Remove a Call From HoldTo Change Phones After Placing a Call on Hold Telephone FCC Interference InformationFCC RF Radiation Exposure Statement Worldwide Headquarters