PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

 

 

 

The measured current is

The charger reached the

No problem, this is a normal

much lower than what was

maximum voltage and is

condition.

selected.

reducing the current.

 

 

 

 

14.BEFORE RETURNING FOR REPAIRS

14.1When a charging problem arises, make certain that the battery is capable of accepting a normal charge. Use a good battery to double check all connections and the AC outlet for a full 120-volts.

14.2When an UNKNOWN OPERATING PROBLEM arises, please read the complete manual and call the customer service number for information that will usually eliminate the need for return.

If the above solutions do not eliminate the problem or for information about troubleshooting

or replacement parts, call toll-free from anywhere in the U.S.A.

1-800-621-5485

7:00 am to 5:00 pm Central Time Monday thru Friday

15.SPECIFICATIONS

Electrical

Nominal Operating Voltage (VAC)

Input Voltage Range (VAC)

Input Current (A max)

Output Power (W)

Output Current (A max)

Output Voltage (VDC max. / maintain)

120

120 ± 10%

15 A

1200

25

61.6 / 52.8

 

Mechanical

Case

 

Steel with Baked Enamel Finish

Dimensions (inches)

 

11 L x 9½ W x 10 ¼ H

Weight

 

40 lbs

 

Connections

AC Power Input Cable

14 Gauge 9’ with NEMA 5.15 Plug

DC Power Output Adapters

8 Gauge 6’ with Polarized 50 Amp Quick

 

Connect Connector

10

Page 14
Image 14
Schumacher INC-14825A owner manual Problem Possible Cause REASON/SOLUTION, Before Returning for Repairs, Specifications