7.3Recommended minimum AWG size for extension cord:

25 feet long or less - use a 12 gauge extension cord.

25 feet to 50 feet long - use a 10 gauge extension cord.

Over 50 feet long - not recommended.

8.FEATURES 3

1

2

 

1.ON/OFF Switch

2.Charging/Charged LED

3.Quick-Connect Connector

9.OPERATING INSTRUCTIONS

Automatic Temperature Compensation

The charger adjusts the maximum charge voltage and maximum maintain voltage based on the ambient air temperature. This permits optimum charging and safety.

Thermal Runaway

The charger automatically reduces the current if it detects the battery may be getting too hot. This is a safety precaution.

Charging

1.Ensure that all of the charger components are in place and in good working condition.

2.Connect the battery to the charger by connecting the quick-connect connector on the charger output cable to the quick-connect connector on the battery.

3.Connect the AC power following the precautions listed in Section 7.

4.Switch the power switch to the ON position to turn the charger on.