Siemens A31008-A200-J101-2-7619 manual Other Settings, Appendix Changing pause after line seizure

Page 32

Gigaset A200 / IM eng / A31008-A200-J101-2-7619 / appendix.fm / 12.06.2003

Appendix

Changing pause after line seizure

You can set the length of the pause that is inserted between pressing the talk key c and sending the phone number (default setting: 3 secs.).

[MENU]

OK[ ]

Press display key to open menu.

Press keys N O 1 L. "916 SET" appears in the display. The number for the currently set pause length flashes. 1 = 1 sec.; 2 = 3 secs.; 3 = 7 secs.; 4 = 2.5 secs.

Enter number and confirm.

Changing pause after recall key (dialling pause)

You can change the length of the dialling pause if your PABX requires this (refer to your PABX operating instructions).

[MENU]

OK[ ]

Press display key to open menu.

Enter N O 1 2. "912 SET" appears in the dis- play. The number for the currently set pause length flashes.

1 = 800 ms; 2 = 1600 ms; 3 = 3200 ms.

Enter number and confirm.

i

To insert a dialling pause between a prefix and a phone number: After entering the prefix, hold down the S key for 2 seconds. A "P" appears in the display. Then enter the phone number.

Other Settings

Factory settings of handset

 

Default settings

Status after

Description

 

 

reset

 

 

 

 

 

Loudspeaker volume

1

1

page 25

Ringer volume

5

5

page 26

Ringtones

1

1

page 26

Directory

empty

unaffected

page 14

Redial list

empty

empty

page 17

Caller list

empty

unaffected

page 18

Network ccess list

empty

unaffected

page 14

Automatic call

activated

activated

page 25

acceptance

 

 

 

Battery warning tone

activated

activated

page 26

Display language

country specific

country specific

page 25,

 

 

 

page 31

30

Image 32
Contents Gigaset Brief overview Brief overviewContents Base station settings Safety precautions Safety precautionsMaking the phone ready for service Making the phone ready for serviceAdvice on a suitable place Positioning the base stationConnecting the base station Making the handset ready for service Remove protective filmInsert batteries Remain pluggedMaking the phone ready for service Switching the handset on and off Activating/deactivating keypad protectionSignal tones Operating the phone and menu managementDisplay keys Operating the phone and menu managementThere are two ways to access a function Display in idle statusMenu management Return from any position in the menu to idle statusTime functions Set date and timeMaking calls Making external calls and ending a callAccepting a call Displaying the callers phone number CLIP/CLIPutting on hold Ending call holdUsing the directory and other lists Directory and network access listUsing the directory and other lists Save phone number in directory network access listDialling with the network access list call-by-call Speed dialling call-by-call from the network access listEither Key in phone number Select phone number from the directoryView entry from directory/network access list and change Delete single entry from directory/network access listDelete directory/network access list Order to use speed dialling EitherRedial list RediallingDelete redial list Copy number from the redial list to the directoryCalling back a caller from the list Caller listOpen caller list and select entry Establish date and time of a call ExampleManual registration Gigaset a 2 handset Registering and de-registering handsetsAutomatic registration Gigaset a 2 handset Specific registration other handsets De-registering handsetsOperating more than one handset Making internal calls and ending callsOperating more than one handset Forwarding a call to another handsetInternal enquiry call Accepting/rejecting a waiting call during an internal callEnd enquiry call Either End internal call, accept external callBarging in on an external call PagingActivating/deactivating the function BargingHandset settings Loudspeaker volumeActivate/deactivate battery warning tone Return handset to factory settingsHandset settings Ringer volume Activate/deactivate ringerBase station settings Return base station to factory default settingsBase station settings Changing the system-PINQuestions and Answers What happens if … Possible cause Possible solutionAppendix AppendixChanging the dialling procedure Setting the flash timeCare Contact with liquidOther Settings Factory settings of handsetDefault settings Status after Description Reset Appendix Changing pause after line seizureAppendix Factory settings of base station Display languageCharacter map and text entry 2 x 3 x 4 x 5 x 6Technical data Power consumptionGeneral technical data Recommended batteriesService Customer Care Excerpt from the original declaration Menu overview Menu overviewMain menu Directory key and network operator list key Index IndexHandset Index Gigaset A200 / IM eng / A31008-A200-J101-2-7619 / coverIV.fm

A31008-A200-J101-2-7619 specifications

The Siemens A31008-A200-J101-2-7619 is a highly regarded model within the Siemens portfolio, known for its robust engineering and advanced functionality. This device is designed to cater to a variety of industrial applications, offering dependable performance that aligns with Siemens’ commitment to quality and innovation.

At the core of the A31008-A200-J101-2-7619 is its state-of-the-art technology, which includes cutting-edge microprocessor control. This feature facilitates precision operations and enables complex calculations to ensure optimal performance. The integration of intelligent software solutions further enhances its capabilities, allowing for seamless communication with other industrial systems. This level of connectivity is vital in automated environments, promoting efficiency and streamlined operations.

One of the main characteristics of the Siemens A31008-A200-J101-2-7619 is its versatility. It is designed to support multiple industrial protocols, ensuring compatibility with a wide range of devices and systems. This adaptability makes it an ideal choice for organizations looking to integrate modern solutions into their existing setups without significant overhauls.

In terms of physical attributes, the A31008-A200-J101-2-7619 boasts a compact design that allows for easy installation in limited spaces. Its robust construction guarantees durability in harsh industrial settings, contributing to reduced maintenance costs and increased operational lifespan. Furthermore, the device is built to withstand extreme temperatures and environmental conditions, making it suitable for outdoor applications as well.

Another noteworthy feature is its energy efficiency, which aligns with modern sustainability goals. The Siemens A31008-A200-J101-2-7619 is engineered to minimize energy consumption while maximizing performance, supporting organizations in their quest for cost-effective and eco-friendly solutions.

User-friendliness is also a significant aspect of this model. The intuitive interface and comprehensive diagnostics tools enable quick system configuration and troubleshooting, which is essential for minimizing downtime.

In conclusion, the Siemens A31008-A200-J101-2-7619 stands out for its advanced technologies, versatility, and robust characteristics, making it an ideal choice for diverse industrial applications. Its balance of performance, energy efficiency, and user accessibility positions it as a reliable component in modern automation systems.