Installation Instructions | ||
Sheet 3 of 4 | ||
|
|
|
Vault w/ visor |
|
| Roundel w/ visor |
These installation instructions are valid with the above Ametrix styles.
Small, INDOOR
SRI
Visor and Non-Visor
Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.
4.
Securing the fixtures with safety wire
(both ceiling grid and drywall)
Safety wire (by others)
Fixture housing
1.After securing fixture housing to ceiling structure using provided brackets, reinforce fixture using safety wire(by others).
2.Using all four tabs located on corners of fixture housing, tie off fixture to structure using safety wire(by others).
5.
| Wiring the fixture |
| (both ceiling grid and drywall) |
| |
Pan head screw | Choose appropriate cover plate |
(2x) | |
| depending on location of power |
| source. |
Ceiling surface
Conduit Nut (by others)
Conduit fitting (by others)
Cover plate
Conduit (by others)
1.If applicable, replace ceiling tile with fixture secured back into ceiling. Remove adjacent tile from ceiling to facilitate wiring.
2.Depending on location of power source, loosen
3.Using conduit fitting and washer, secure conduit to cover plate.
4.Attach appropriate wires and ensure all connections are properly matched.
5.Replace cover plate and secure with
ADY071458 REV A (ECN070344)