Linear AE-1000 Optional Postal Lock, Optional Color Cctv Camera, Postal Lock Installation

Page 13

Optional Postal Lock

A postal lock can be installed in the AE-1000 Entry System to provide keyed access for the postal service. The AE-1000 case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate.

Postal Lock Installation

1.Remove the four locknuts that retain the postal lock switch plate (above the speaker on the AE-1000 faceplate).

2.Remove the switch plate hole cover plate, and block from the four studs. The hole cover plate and block will not be used and can be discarded.

3.Install the postal lock assembly onto the four studs. The postal lock’s moving plunger should point towards the middle of the faceplate (see fi gure).

4.Replace the postal lock switch plate with the microswitch oriented inward where it will be pressed by the postal lock’s moving plunger (see fi gure).

5.Secure the postal lock and switch plate with the four locknuts.

NOTE: Be sure the postal lock’s plunger actuates the microswitch. Adjust the switch plate and the postal lock then test the action until the microswitch fully actuates.

1REMOVE LOCKNUTS

3INSTALL POSTAL LOCK

PLUNGER POINTS

TO LEFT

2REMOVE PLATE

4REPLACE PLATE WITH THE MICROSWITCH TOWARDS THE FRONT OF THE CABINET, REPLACE LOCKNUTS

6.Tighten the four locknuts after the adjustment and testing is complete.

7.When programming the system, set the postal lock option to activate the desired relay output.

NOTE: BE SURE THE POSTAL LOCK'S PLUNGER ACTUATES THE MICROSWITCH. ADJUST THE SWITCH PLATE AND THE POSTAL LOCK THEN TEST THE ACTION UNTIL THE MICROSWITCH FULLY ACTUATES

Optional Color CCTV Camera

Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed inside the AE-1000 Entry System. The camera provides a video signal for viewing the area in front of the entry system.

The CAMERA connector is used to connect the camera to the AE-1000. The 4-conductor cable routes power to, and video from the camera. The VIDEO jack is the camera output for connection to a video cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.

Camera Installation

1.Remove the two locknuts and the cover plate from the camera mounting studs above the keyswitch on the AE-1000 faceplate.

2.Mount the camera assembly on the two studs, with the alignment hole in the camera bracket towards the top. Secure the camera with the two locknuts.

3.Connect the camera’s cable to the AE-1000’s CAMERA connector.

4.Connect the video cable to the AE-1000’s VIDEO connector.

5.Connect the other end of the video cable to the viewing monitor or the video distribution system.

1 REMOVE PLATE RETAINING NUTS

2 REMOVE THE PLATE

COVER PLATE

3 INSTALL THE GASKET

4 REMOVE THE LENS CAP

GASKET

 

5 ATTACH CAMERA WITH TWO NUTS

6

CONNECT

 

 

CAMERA

HOLE

WIRING

ON TOP

HARNESS

 

7

 

CONNECT

 

VIDEO

 

CABLE

13

Image 13
Contents AE-1000 Introduction ContentsOperation Feature Overview Hardware FeaturesSoftware Highlights Pbus Accessories Accessory OverviewWiegand Accessories Component Locations Installation NoteThis Wiring Example Shows Wiring DiagramImportant Mounting Requirements Mounting Preparation Entry System MountingSurface Mounting Surface MountingPedestal Mounting Recessed MountingDoor or Pedestrian Gate Control Relay Output WiringGate Control Request-to-Exit InputsPower Wiring Power, Battery, & Ground WiringBackup Battery / Uninterruptable Power Supply Earth GroundImportant Telephone Wiring Tips Telephone WiringTypical Telephone Wiring Optional Radio AntennaCamera Installation Postal Lock InstallationOptional Postal Lock Optional Color Cctv CameraWiegand Accessories Pbus AccessoriesOptional Network Connection Mount and install the units for the networkNetwork with Hub Network Daisy-chainSystem Adjustments On-board Pushbuttons Internal ControlsOn-board Display Requesting Access with a Wireless Transmitter Requesting Access with an Entry CodeRequesting Access with a Visitor Call AE-1000 OperationSpecifications Dimension Drawing16-1/4 18-3/8Troubleshooting