Linear AE-1000 Entry System Mounting, Mounting Preparation, Surface Mounting

Page 8

Entry System Mounting

The AE-1000 cabinet is designed to be mounted three ways:

The unit can be mounted directly to a wall or fl at surface.

The unit can be mounted recessed into the wall.

The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access for power, telephone, earth ground, control output must be available to the mounting location. If the optional remote accessories are used, wiring access for these cables must also be available to the mounting location.

Mounting Preparation

Before mounting the system, the main circuit board mounting plate must be removed to provide access for the wiring hole and mounting fasteners.

CAUTION!: Touch a grounded object before proceeding to discharge static electricity from your body.

1GROUND WIRE STUD

CAREFULLY REMOVE THE FOUR WIRING HARNESS CONNECTORS & GROUND WIRE

MOUNTING

PREPARATION

2

LOOSEN THE TOP TWO NUTS & REMOVE THE BOTTOM TWO NUTS

1.Carefully remove the four main circuit board wiring connectors:

• The CPU/interface ribbon cable connector.

• The processor module power connector.

• The telephone interface connector.

• The tamper switch connector.

2.Remove the nut from the Earth Ground stud and remove the green ground wire lug from the stud.

3.Remove the two bottom circuit board mounting plate nuts.

4.Loosen the two top circuit board mounting plate nuts.

5.Carefully lift up on the mounting plate, removing the circuit board mounting plate. Set it aside in a safe place.

Reverse these steps to replace the circuit board mounting plate after the cabinet mounting is complete.

Surface Mounting

The cabinet can be mounted on a wall or any suitable fl at surface. The four 3/8” mounting holes or the four self-drill locations can be used to attach the cabinet to the surface.

1.For wall mounting, hold the cabinet at the approximate mounting location where the display will be about eye level or slightly above.

2A. If using the 3/8” mounting holes, mark the four mounting hole centers. Drill as required. Use the appropriate fasteners for the mounting surface to secure the cabinet.

2B. If using the self-drill mounting holes, choose the correct size bit for the fasteners and drill the cabinet as required. Use the appropriate fasteners for the mounting surface to secure the cabinet.

3.After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.

3CAREFULLY REMOVE THE CIRCUIT BOARD

SURFACE

MOUNTING

OR

1 MARK THE FOUR MOUNTING HOLES

DRILL THE CABINET AT THE

PRE-MARKED LOCATIONS

2

ATTACH THE CABINET WITH APPROPRIATE

 

HARDWARE FOR THE MOUNTING SURFACE

8

Image 8
Contents AE-1000 Operation ContentsIntroduction Software Highlights Hardware FeaturesFeature Overview Wiegand Accessories Accessory OverviewPbus Accessories Installation Note Component LocationsWiring Diagram This Wiring Example ShowsImportant Mounting Requirements Entry System Mounting Mounting PreparationSurface Mounting Surface MountingRecessed Mounting Pedestal MountingRelay Output Wiring Door or Pedestrian Gate ControlGate Control Request-to-Exit InputsPower, Battery, & Ground Wiring Power WiringBackup Battery / Uninterruptable Power Supply Earth GroundTelephone Wiring Important Telephone Wiring TipsTypical Telephone Wiring Optional Radio AntennaPostal Lock Installation Camera InstallationOptional Postal Lock Optional Color Cctv CameraPbus Accessories Wiegand AccessoriesMount and install the units for the network Optional Network ConnectionNetwork with Hub Network Daisy-chainSystem Adjustments On-board Display Internal ControlsOn-board Pushbuttons Requesting Access with an Entry Code Requesting Access with a Wireless TransmitterRequesting Access with a Visitor Call AE-1000 OperationDimension Drawing Specifications16-1/4 18-3/8Troubleshooting