Linear AE-1000 installation instructions Pbus Accessories, Wiegand Accessories

Page 14

PBUS Accessories

Several accessories (keypads, proximity readers, remote receivers) can be connected to the AE-1000’s three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate.

Linear’s PBUS devices compatible with the AE-1000 are:

AM-RRR Remote Radio Receiver

AM-RPR Radio Proximity Receiver

AM-KP Exterior Keypad

AM-KPI Interior Keypad

AM-CRI Card Reader Interface

1. Mount and install the accessory as described in its installation

instructions.

NOTE: UP TO SIX PBUS DEVICES MAY BE CONNECTED TO THE THREE SETS OF AM-1000

PBUS TERMINALS

PWR

GND

REMOTE DAT1

PBUS

DAT0

DEVICE

DVAL

PCLK

PBUS

TERMINALS

PWR

GND

DAT1

DAT0

DVAL

PCLK

2. Route 6-conductor cable from the AE-1000 to the accessory.

For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.

For wire runs up to 600 feet use 20 AWG Weico Type 9405 or equivalent.

3.Set the DEVICE ADDRESS rotary switch in the accessory to a unique address number. When programming the system, the device address number will identify each PBUS accessory to the AE-1000.

4.Connect the 6-conductor cable to the accessory and the AE-1000.

SET THE REMOTE DEVICE ADDRESS SWITCH TO A UNIQUE DEVICE ADDRESS

Wiegand Accessories

The two AE-1000 Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.

NOTE: Depending on the Wiegand accessory used, the LED1, LED2, and HOLD connections may not be required.

LED1 output is switched to ground during non-access time.

LED2 output is switched to ground for one second during access

time.

1.Mount and install the Wiegand accessory as described in its installation instructions.

2.Route a cable from the AE-1000 to the accessory.

For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.

For wire runs up to 500 feet use 20 AWG Weico Type 9405 or equivalent.

LED2

HOLD REMOTE LED1 WIEGAND DAT1 DEVICE DAT0 GND PWR

WIEGAND

TERMINALS

LED2

HOLD

LED1

DAT1

DAT0

GND

PWR

3.Connect the cable to the accessory and the AE-1000 as shown in the fi gure.

NOTE: THE LED1, LED2, AND HOLD CONNECTIONS MAY NOT BE REQUIRED DEPENDING ON THE WIEGAND DEVICE USED

14

Image 14
Contents AE-1000 Operation ContentsIntroduction Software Highlights Hardware FeaturesFeature Overview Wiegand Accessories Accessory OverviewPbus Accessories Installation Note Component LocationsWiring Diagram This Wiring Example ShowsImportant Mounting Requirements Surface Mounting Entry System MountingMounting Preparation Surface MountingRecessed Mounting Pedestal MountingGate Control Relay Output WiringDoor or Pedestrian Gate Control Request-to-Exit InputsBackup Battery / Uninterruptable Power Supply Power, Battery, & Ground WiringPower Wiring Earth GroundTypical Telephone Wiring Telephone WiringImportant Telephone Wiring Tips Optional Radio AntennaOptional Postal Lock Postal Lock InstallationCamera Installation Optional Color Cctv CameraPbus Accessories Wiegand AccessoriesNetwork with Hub Mount and install the units for the networkOptional Network Connection Network Daisy-chainSystem Adjustments On-board Display Internal ControlsOn-board Pushbuttons Requesting Access with a Visitor Call Requesting Access with an Entry CodeRequesting Access with a Wireless Transmitter AE-1000 Operation16-1/4 Dimension DrawingSpecifications 18-3/8Troubleshooting