3Com MS40-717X warranty Applicable Literature, Specifications, Inputs, Outputs

Page 2

Applicable Literature

F-Number

Description

 

Audience

Purpose

 

 

 

 

 

 

 

Sales Personnel

Describes the globe valve

 

MX40-6XXX-2XX, MX40-7XXX-2XX Series

Application Engineers

actuator/linkage assembly’s features,

F-26750

Installers

specifications, and possible applications.

Actuator/Linkage Assemblies General Instructions

 

Service Personnel

Provides step-by-step mounting

 

 

 

 

Start-up Technicians

instructions.

 

 

 

 

 

 

 

Sales Personnel

Provides actuator specifications and part

 

 

Application Engineers

 

MX40-7XXX, MX40-6XXX Series DuraDrive Actuator

number cross referencing of phased out

F-26646

Installers

Selection Guide

actuators with the new direct-coupled

 

Service Personnel

 

 

actuators.

 

 

Start-up Technicians

 

 

 

 

 

 

 

 

 

VX-2000, VX-7000 Series

Sales Personnel

Provides part number cross referencing of

 

Application Engineers

 

MX40-7XXX, MX40-6XXX Series

F-26752

Installers

phased out actuators with the new direct-

Ball/Linked Globe Valve Assemblies

 

Service Personnel

coupled actuators.

 

Actuator/Linkage Assemblies Selection Guide

 

Start-up Technicians

 

 

 

 

 

 

 

 

 

 

 

Application Engineers

Describes Schneider Electric approved

F-26080

EN-205 Water System Guidelines

Installers

Service Personnel

water treatment practices.

 

 

 

 

Start-up Technicians

 

 

 

 

 

 

F-13755

CA-28 Control Valve Sizing

Application Engineers

Provides charts, equations, and diagrams

 

 

to assist in the configuration of valve

F-11080

Valve Selection Chart Water

Installers

system applications. TOOL-150, valve

 

 

Service Personnel

F-11366

Valve Selection Chart Steam (two-way valves only)

sizing slide rule may be purchased

Start-up Technicians

separately.

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Inputs

Control Signal: 4 to 20 mAdc (with the addition of a 500 Ohm resistor - not included) or 2 to 10 Vdc. See Figure-1through Figure-8.

Power Input: See Table-1.All 24 Vac and 22-30 Vdc circuits are Class 2. All circuits 30 Vac and above are Class 1.

Impedance: 2 to 10 Vdc, 121kΩ. 4 to 20 mAdc, 500Ω. (user supplied).

Connections:

Class 1 Power, 24 inch (61 cm) long, 18 AWG color coded pigtail leads.

Class 2 Power & Control, 36 inch (91 cm) long, 22 AWG color coded appliance cable leads.

Ground, 36 inch (91 cm) long, 18 AWG green/yellow pigtail lead.

Outputs

Electrical:

Position Feedback Voltage, “AO” 2 to 10 Vdc (max. 0.5 ma) output signal for position feedback or to operate up to four additional slave actuators.

Stroke, Electronically limited to 92° ±1°.

Action, Direct acting, 0° position with 4 mAdc or 2 Vdc input. Torque See Table-1.

Duty Cycle 100%.

Timing See Table-1.

Mechanical:

Anti-Rotation Bracket,

Standard 9" long x 13/16" wide (229 x 21 mm), included with the actuator. Optional Order AM-752 (4" long x 1-11/16" wide) for mounting the actuator in narrow spaces.

Universal Mounting Clamps, Two clamps are required for all mounting configurations. Standard 3/8" to 1/2" (10 to 13 mm) round and square shaft mounting clamps are included with the actuator.

Optional Order AM-753 for 5/8" (16 mm) square and 3/4" to 1" (19 to 25 mm) round damper shafts, two per package.

2

Copyright 2010 Schneider Electric All Rights Reserved.

F-26748-6

Image 2
Contents MS40-717X Series Inputs SpecificationsApplicable Literature OutputsEnvironment Ambient Temperature LimitsModel Chart Agency ListingsTypical Applications wiring diagrams GRDTypical MS40-7171 2 to 10 Vdc Wiring Diagram Power Wiring Identification Voltage Designation Wire ColorRequirements InstallationInspection Federal Communications Commission FCC PrecautionsGeneralLocationCaution Canadian Department of Communications DOCDamper Actuator Sizing Steel Damper Shaft SpecificationsMounting Damper Shaft SizingLong Damper Shafts Centerline Mounting Anti-rotation Bracket to Actuator Short Damper Shafts Control and Power Wiring Data Wiring RequirementsControl and Power Leads Wire Color Codes for Models Manufactured before DecemberTheory of Operation MaintenanceCheckout Field RepairDimensional Data 10-27/32