VS-900 Architects and Engineering Specifications v1.0

The Direct Select Interface Card shall include an RS-232C D-sub connector, 9-pin, female for programming the connected Direct Select I/O Card(s). The DSI shall include an integral 6-position 4-contact RJ11-type modular plug and connect to the Master Station port with twisted pair cable. When using the Master Station, the maximum cable distance shall be the total connected distance from the exchange to the Master Station via the VS-900DI and shall be #20 AWG: 7546 ft./1.43 mile (2.3 km); #22 AWG: 4921 ft./0.93 mile (1.5 km); #24 AWG: 2953 ft./0.56 mile (0.9km).

The Direct Select Interface Card shall be the TOA VS-900DI.

2.5.2 DIRECT SELECT I/O (INPUT/OUTPUT) CARD

The Direct Select I/O (DSIO) Card shall connect to the Direct Select Interface Card and provide 32 sets of I/O connections. Each I/O set shall include a relay, call LED driver and direct select input. System programming shall allow the user to associate each I/O set with a Master Station or Sub-station. The Direct Select Interface Card shall support a maximum of thirty-two (32) DSIO Cards. Each relay shall be normally-open type with contact capacity of 24 V DC/1 A. System programming shall allow global configuration of the relay activation mode as call-in or answer- activated. Each Call LED output (for LED indication of incoming and outgoing calls) shall be open collector-type, 24 V DC/100 mA. A current limiting resistor shall be required in series with each LED. Each Direct Select Input contact (for calling and response switch operation) shall be activated with a dry contact switch closure with a rating of 5 VDC/0.5 mA and contact resistance of less than 50 ohms. The DSIO Card shall require an external 24 VDC/1 A power supply. Each type of I/O shall require a 50-position "CHAMP" IDC type (Amphenol type) connector.

The Direct Select I/O Card shall be the TOA VS-910DI.

2.5.3 DIRECT SELECT POWER SUPPLY

The Direct Select Power Supply shall provide 24 VDC with rated 3 A current capacity to support one Direct Select Interface Card and two Direct Select I/O Cards.

The Direct Select Power Supply shall be the TOA XPS-24VS.

2.6 REMOTE CONTROL AND MONITORING

The security intercom system shall allow external remote control and monitoring of intercom system functions through the exchange mainframe serial port. The intercom manufacturer shall provide a serial communication protocol document. The installing contractor shall be solely responsible for the correct operation and performance of the security intercom system and all external equipment connected to the intercom system.

11

Image 11
Contents VS-900 System Configuration and Components VS-900 Architects and Engineering SpecificationsRemote Call Forwarding Call Capture Qualifications Service FacilitiesManufacturer ContractorDESKTOP/WALL-MOUNT Master Station System DescriptionSystem Station Capacity Station EquipmentOutdoor SUB-STATION Economy SUB-STATIONIndoor SUB-STATION Panic SUB-STATION Master Station Line Card Power Supply UnitExchange Components Exchange MainframeAudio Function Card Telephone Master Station Line CardSUB-STATION Line Card 6 C/O Telephone Line CardDirect Select Interface Site Connector TIE-LINE InterfacePeripheral Components TIE-LINE Interface CardDirect Select I/O INPUT/OUTPUT Card Remote Control and MonitoringDirect Select Power Supply Conversation Modes Station CommunicationCALL-IN TIME-OUT Conversation TIME-OUTAUTO-DIAL Calling Party DisplaySUB-STATION Priority Level Selective RESPONSE/CALL QueueCall Hold CAMP-ON-BUSYGroup Call Call TransferNO-ANSWER Call Forwarding Scan MonitorOutside Telephone Line Call Forwarding TIME-BASED Outside Telephone Line Call ForwardingPaging ConferenceEmergency Conference Telephone Line Functions External Source DistributionConversation Recording