TOA Electronics VS-900 manual Telephone Master Station Line Card, SUB-STATION Line Card

Page 9

VS-900 Architects and Engineering Specifications v1.0

ft./1.43 mile (2.3 km); #22 AWG: 4921 ft./0.93 mile (1.5 km); #24 AWG: 2953 ft./0.56 mile (0.9km).

The Master Station Line Card shall be the TOA VS-900MS.

2.4.4 TELEPHONE MASTER STATION LINE CARD

The Telephone Master Station Line Card shall be powered by the Exchange Mainframe and provide connection ports for two DTMF-based analog telephones designed in compliance with FCC Part 68 with support for Caller-ID signaling. Each Telephone Master Station port shall have an associated recording output, 0 dBV, unbalanced and a control activation port, open collector, 24 VDC maximum, 20 mA. Control activation shall occur immediately after communication has been established and deactivate immediately after communication has been terminated.

Each Telephone Master Station shall connect to a unique Telephone Master Station Line Card port with a single twisted pair cable with total loop resistance, including telephone, to be no greater than 500 ohms.

The Telephone Master Station Line Card shall be the TOA VS-900AL.

2.4.5 SUB-STATION LINE CARD

The Sub-station Line Card shall be powered by the Exchange Mainframe and provide connection ports for sixteen Sub-stations. Two links: one voice link and one voice/paging link shall allow two simultaneous conversations or one conversation and one paging function. Conversation method shall be half-duplex by voice-operated switch controlled by the Master Station or Telephone Master Station and simplex conversation by PTT switch controlled by the Master Station. The combined maximum power output shall be 6 W at 25 V line. A paging output, unbalanced, -20 dBV and paging input, balanced, 25 V line, 30 W maximum shall allow connection of an external amplifier for sub-station paging.

Each Sub-station shall connect to a unique Sub-station Line Card port with a single, shielded, twisted pair cable with the following wire gauges and maximum service distances: #20 AWG: 4265 ft./0.81 miles (1.3 km); #22 AWG: 2625 ft./0.5 miles (0.8 km); #24 AWG: 1,640 ft./0.31 miles (0.5 km).

The Sub-station Line Card shall be the TOA VS-900RS.

2.4.6 C/O TELEPHONE LINE CARD

The Outside Telephone Line Card shall be powered by the Exchange Mainframe and provide connection ports for two outside telephone lines or trunks in compliance with FCC Part 68 regulations. The C/O Telephone Line Card shall be compatible with both loop and ground start systems and use DTMF dialing. Each telephone line port shall have an associated recording output, 0 dBV, unbalanced and a control activation port, open collector, 24 VDC maximum, 20 mA. Control activation shall occur immediately after communication has been established and deactivate immediately after communication has been terminated.

The C/O Telephone Line Card shall be the TOA VS-900CO.

2.4.7 AUDIO FUNCTION CARD

The Audio Function Card shall be powered by the Exchange Mainframe and provide the following: one paging line output, 0 dBV, unbalanced with sixteen associated open collector control outputs, 24 VDC maximum, 20 mA; one line input for external source distribution, 0 dBV, unbalanced with four associated trigger inputs, no-voltage make contact, open voltage: 24 VDC, short circuit current: 20 mA; and one Conference/Emergency Conference link to allow simultaneous communication/conversation between multiple Master Stations and/or Telephone Master Stations.

9

Image 9
Contents VS-900 System Configuration and Components VS-900 Architects and Engineering SpecificationsRemote Call Forwarding Call Capture Manufacturer Service FacilitiesContractor QualificationsSystem Station Capacity System DescriptionStation Equipment DESKTOP/WALL-MOUNT Master StationEconomy SUB-STATION Indoor SUB-STATIONOutdoor SUB-STATION Panic SUB-STATION Exchange Components Power Supply UnitExchange Mainframe Master Station Line CardSUB-STATION Line Card Telephone Master Station Line Card6 C/O Telephone Line Card Audio Function CardPeripheral Components Site Connector TIE-LINE InterfaceTIE-LINE Interface Card Direct Select InterfaceRemote Control and Monitoring Direct Select Power SupplyDirect Select I/O INPUT/OUTPUT Card CALL-IN TIME-OUT Station CommunicationConversation TIME-OUT Conversation ModesSUB-STATION Priority Level Calling Party DisplaySelective RESPONSE/CALL Queue AUTO-DIALGroup Call CAMP-ON-BUSYCall Transfer Call HoldOutside Telephone Line Call Forwarding Scan MonitorTIME-BASED Outside Telephone Line Call Forwarding NO-ANSWER Call ForwardingConference Emergency ConferencePaging Telephone Line Functions External Source DistributionConversation Recording