VS-900 Architects and Engineering Specifications v1.0

2.4 EXCHANGE COMPONENTS

2.4.1 EXCHANGE MAINFRAME

The Exchange Mainframe shall be modular and support up to four (4) Master Stations or Telephone Master Stations and sixty-four (64) Sub-stations. Each mainframe shall have the capacity to accept two Master Station or Telephone Master Station Line Cards, four Sub-station Line Cards, one C/O Telephone Line Interface Card, one Audio Function Card and one Tie-Line Interface Card. All system cards shall have removable terminal blocks for solderless wiring terminations.

The Exchange Mainframe shall require up to two external Power Supply Units with a maximum current consumption of 7 A. A 24 VDC input shall be available for use with a backup power supply to maintain operating capability in the event of AC Mains power failure. The Exchange Mainframe shall have a Power ON/OFF switch and LED’s for Power and Status indication. System cards shall connect to an integral backplane motherboard with onboard microprocessor, real-time clock and an internal power supply board with field-replaceable fuses. The speech path configuration shall be a time sharing switch with twelve types of internal sound sources. System programming shall be performed exclusively with an external computer and all parameters shall be stored in EEPROM. Systems requiring a backup battery for programming data storage shall not be acceptable. Two RS-232C ports, D-sub connector, 9-pin, female shall be available for separate programming and data logging connections.

Operating temperature range shall be +32 to +104 degrees F (0 to +40 degrees C). The enclosure finish shall be pre-coated steel plate, black, and 30% gloss. Dimensions (W x H x D), excluding the rack mounting bracket, shall be 16.54” x 17.47” x 11.35” (420 x 443.7 x 288.3 mm) and weight shall be 28 lbs. (12.7 kg). The exchange mainframe shall be rack-mountable and occupy (10) EIA 19” rack spaces. An accessory wall-mount bracket shall be available with material and finish steel, black, electrode position paint with dimensions (W x H x D) of 15.41” x 17.32” X 2.28” (391.4 x 440 x 58 mm) and weight of 4.63 lbs. (2.1 kg). System programming software, installation/operators manuals shall be included with each mainframe.

The Exchange Mainframe shall be the TOA VS-900MF.

The Exchange Wall-Mount Bracket shall be the TOA YC-303.

2.4.2 POWER SUPPLY UNIT

The Power Supply Unit shall provide two 20 VAC, 2 A AC outputs to the Exchange Mainframe and support a maximum of 2 Sub-station Line Cards. The AC mains power requirements shall be 110/120 VAC, 50/60 Hz. An optional rack-mount panel shall allow side-by-side rack mounting of two Power Supply Units and occupy four (4) EIA 19” rack spaces. The material and finish shall be steel plate with ivory color with dimensions (W x H x D) of 6.30” x 2.68” x 7.01” (160 x 68 x 178 mm) and weight of 6.17 lbs. (2.8 kg).

The Power Supply Unit shall be the TOA PU-200.

The Rack Mount Panel shall be the TOA PN-100B.

2.4.3 MASTER STATION LINE CARD

The Master Station Line Card shall be powered by the Exchange Mainframe and provide connection ports for two Master Stations. Each Master Station port shall have an associated recording output, 0 dBV, unbalanced and a control activation port, open collector, 24 VDC maximum, 20 mA. Control activation shall occur immediately after communication has been established and deactivate immediately after communication has been terminated.

Each Master Station shall connect to a unique Master Station Line Card port with a single twisted two pair cable with the following wire gauges and maximum service distances: #20 AWG: 7546

8

Image 8
Contents VS-900 VS-900 Architects and Engineering Specifications System Configuration and ComponentsRemote Call Forwarding Call Capture Service Facilities ManufacturerContractor QualificationsSystem Description System Station CapacityStation Equipment DESKTOP/WALL-MOUNT Master StationOutdoor SUB-STATION Economy SUB-STATIONIndoor SUB-STATION Panic SUB-STATION Power Supply Unit Exchange ComponentsExchange Mainframe Master Station Line CardTelephone Master Station Line Card SUB-STATION Line Card6 C/O Telephone Line Card Audio Function CardSite Connector TIE-LINE Interface Peripheral ComponentsTIE-LINE Interface Card Direct Select InterfaceDirect Select I/O INPUT/OUTPUT Card Remote Control and MonitoringDirect Select Power Supply Station Communication CALL-IN TIME-OUTConversation TIME-OUT Conversation ModesCalling Party Display SUB-STATION Priority LevelSelective RESPONSE/CALL Queue AUTO-DIALCAMP-ON-BUSY Group CallCall Transfer Call HoldScan Monitor Outside Telephone Line Call ForwardingTIME-BASED Outside Telephone Line Call Forwarding NO-ANSWER Call ForwardingPaging ConferenceEmergency Conference External Source Distribution Telephone Line FunctionsConversation Recording