Aiphone GFO-1DLF specifications Programming & Operation

Page 3

PROGRAMMING & OPERATION:

PROGRAMMING THE SYSTEM (INDIVIDUAL BUTTON PANEL):

1.Remove faceplate of GF entrance panel.

2.Lift rubber cap located on the upper right side of the GF-DA/B speaker module.

3.Using a long slender tool, momentarily press the programming button through the hole inside the GF-DA/B.

4.The In-Use LED will blink for approximately 15 seconds, then will become steadily lit.

5.With In-USE LED steadily lit, press the TALK button momentarily on the GFO-1DL you wish to program. (Only one station can be programmed at a time.) Communication will be present (push-to-talk, release-to-listen at unit).

6.Momentarily press the call button in the GF-SW that is designated to call that tenant station. A single beep will be heard.

7.Press END button on GFO-1DL. (This is like hanging up the handset on a standard GF-1DK model.)

8.If the tenant has a second room station:

8a. Press the second unit's TALK button momentarily. Communication will be present.

8b. Press the same call button on the entrance panel. Two beeps will be heard.

8c. Press END button.

NOTE: If five beeps are heard when programming, that is an error indication. Clear the station by pressing and holding the call button on the panel until a continuous beep is heard. Then reprogram by momentarily pressing the call button again and releasing. A short single beep will be heard.

9.Repeat steps 5 through 8c to program each room station.

10.When programming is completed, press programming switch in GF-DA/B again. In-Use LED will turn off.

11.The system is now in regular operating mode.

12.Secure the rubber cap and replace the front panel.

13.Repeat the above programming process for each entrance panel in the system.

Put Entrance panel in

program mode.

Press TALK button of

station to be programmed.

Press designated call button

Press program button in

GF-DA/B again to return to

in GF-SW momentarily.

normal operation mode.

 

Press END button on GFO-1DL after it has been programmed.

Program each station in the system in the same manner.

PROGRAMMING DIGITAL ENTRANCE PANEL* TO CALL GFO-1DL ROOM STATIONS:

* NOTE: Program tenant's 3 or 4 digit number and name into the GF-NS/A first. Use computer program that comes with the GF-NS/A or enter manually, as shown in the GF-NS/A instructions.

1~5. Follow steps 1 through 5 as described above.

6.Scroll to tenant's name or number (or enter number with keypad) on entrance panel, then momentarily press BELL button (green-lit BELL symbol). A short beep will be heard.

7.Press END button on GFO-1DL. (This is like hanging up the handset on a standard GF-1DK model.) 7a. Program second room station the same way, and two beeps will be heard.

8.Continue programming each station in the system in this manner.

Refer to GF-NS/A Instructions for more detail on programming the digital scroll module.

PROGRAMMING THE CONCIERGE STATION (GF-MK) TO CALL GFO-1DL ROOM STATIONS:

1.Put GF-MK into programming mode as described in GF-MK Instructions, page 2-3.

2.Lift handset on GF-MK first.

3.At tenant station to be programmed, press TALK button. Communication will be established.

4.Scroll to tenant's name or number (or enter number with keypad), then momentarily press BELL button (green-lit BELL symbol). A short beep will be heard.

5.Press END button on GFO-1DL. (This is like hanging up the handset on a standard GF-1DK model.)

5a. Program second room station the same way, and two beeps will be heard.

6.Continue programming each room station in the same manner, then go out of programming mode to return to normal operation.

Refer to GF-MK Instructions for more detailed information on concierge programming.

Pg. 3

 

Image 3
Contents Names & Functions KEY Symbol PressBell Symbol Press Talk first, then Bell button Volume ControlsTerminal Locations Wiring DiagramSurface Mount Installation Flush Mount InstallationPress END button on GFO-1DL after it has been programmed Programming & OperationOperation Troubleshooting GuideSpecifications FCC Class B VerificationToll Free Technical Support

GFO-1DL, GFO-1DLF specifications

The Aiphone GFO-1DLF and GFO-1DL intercom systems represent cutting-edge advancements in communication technology, designed to enhance safety and convenience in various environments. These models are part of Aiphone's commitment to delivering reliable and efficient intercom solutions, suitable for residential, commercial, and institutional applications.

One of the defining features of the GFO-1DLF and GFO-1DL is their high-quality audio and video capabilities. Equipped with a 7-inch color LCD monitor, these intercoms provide clear video images, allowing users to see who is at the door or entering a specific area. The resolution ensures that details are captured accurately, enhancing security and helping users make informed decisions.

Another key characteristic is the flexibility offered by these devices. The GFO-1DLF model includes a camera with a wide-angle lens, ensuring a broader field of view. This feature is particularly beneficial in monitoring entry points without requiring the user to manually adjust the camera. Additionally, the system supports two-way communication, making it easy for users to converse with visitors or staff without the need for physical presence.

Both intercom models utilize advanced digital technology, which significantly reduces interference and enhances audio clarity. The noise-canceling feature particularly stands out, as it minimizes background sounds, allowing users to focus on the conversation at hand. This adds to the overall user experience, making communication seamless and effective.

Moreover, the Aiphone GFO series stands out for its ease of installation and integration. The intercoms can be connected to existing wiring systems, simplifying the setup process. Wireless options are also available, providing users with more flexibility regarding their communication infrastructure. The systems are compatible with various Aiphone accessories, expanding their functionality and versatility.

Safety is paramount in any intercom system, and Aiphone has included features such as a locking mechanism for doors and gates, which can be controlled directly from the intercom unit. Users can grant access remotely, ensuring security without compromising convenience.

With these characteristics, the Aiphone GFO-1DLF and GFO-1DL intercoms offer a powerful combination of audio-visual clarity, user-friendly operation, and enhanced security features. As technology continues to evolve, these intercom systems reflect a commitment to innovation and efficiency, making them a wise choice for anyone looking to upgrade their communication capabilities.