Aiphone GFO-1DLF specifications Operation, Troubleshooting Guide

Page 4

OPERATION:

1.Press the tenant's call button on the entrance panel, and a ring tone will be heard at the tenant station.

1a. If a digital entrance panel is used, enter the tenant's 3 or 4 digit code or scroll to their name, then press the green-lit "bell" button on the entrance panel.

2.Answer the call at the tenant station by pressing the TALK button. NOTE: There is a brief delay when initially pressing TALK, so pause for approximately one second before speaking.

3.Release TALK button to listen to the calling visitor. To speak to caller again, press TALK button. There is no delay on subsequent presses of the TALK button.

4.To activate the door release, momentarily press the KEY symbol button. This will activate the door release mechanism at the calling entrance panel. The duration of the release is determined by the door release timer setting on the back of the GF-DA/B audio module.

5.To end the conversation, press END button. If END is not pressed, the communication path will automatically time out after approximately 2-1/2 minutes.

NOTE: If the END button was not pressed at the end of the previous call, it must be pressed first before pressing the TALK button to answer a new incoming call.

Call from Entrance panel

Answer the call at the

Press "key" symbol

 

 

 

 

 

or Concierge Station

tenant station by

Press END button to

button to release

 

pressing TALK button to

conclude the call.

 

the door.

 

talk, release to listen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

END

 

 

Note: Above graphics are not an exact replication of the GFO-1DL, but are for illustration purposes only.

TROUBLESHOOTING GUIDE:

 

 

 

 

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

When in program mode, press and release call button

 

 

 

quickly. Do not hold button down too long, which

 

Audio works in programming mode, but after

 

actually clears the programming for that station. When

 

programmed, can't call or communicate with room

Holding call button down too long

programming with digital panel, dial number, then press

 

station.

when programming.

and release green "bell" button.

 

 

Another station has been

Press and hold call button until solid beep is heard at

 

When programming the first station in an

programmed on that channel and

entrance while in programming mode to clear the

 

apartment, 2 beeps are heard instead of 1 beep

the 2 beeps indicate a 2nd station

memory. Press again once and release. If 1 short beep

 

(Two beeps should be heard only when

programmed on the same call

is heard, programming is correct. If 5 short beeps are

 

programming 2nd unit in each apartment)

button.

heard, clear again and reprogram.

 

When programming, 5 beep tones in rapid

 

Clear the programming by pressing the call button and

 

succession are heard instead of the normal single-

Programming done improperly, or

holding it until you hear a solid tone, then reprogram. If

 

or double-beep tones.

wiring is not correct.

that does not work, double check wire connections.

 

 

 

Make sure that the END button is pressed on each

 

 

 

station after it's been programmed. Only the station

 

 

 

being programmed should be in the communication

 

No communication at GFO-1DL in program mode,

END button not pressed on

mode with the entrance station. Go to each station in

 

even with TALK button pressed.

another station in the system

the system and make sure END button is pressed.

 

 

 

If more than one entrance station is set to the same

 

LED on GF-DA at entry panel does not light, panel

 

identification number (1 - 5) the program button will not

 

emits high-pitched squeal. Program button does

Panel identification DIP switches

work. The LED will not light and entrance panel will emit

 

not work.

set improperly.

a high pitched whistle.

 

In program mode, system will not give the

 

 

 

 

 

acknowledgement beep or the clear tone when

Wire changes made with power

Cycle system power to any / all bus controllers present

 

holding down the button.

applied, or ground fault.

(GF-BC, GF-VBC, etc).

 

 

 

After entering program mode on GF-MK, handset on

 

 

 

that unit must be picked up first before pressing TALK

 

 

 

button on GFO-1DL. If no communication, press END

 

 

 

button on GFO-1DL, then pick up GF-MK handset. Then

 

Can't establish communication in program mode

 

press TALK button on room station and communication

 

between GF-MK and GFO-1DL.

Not following proper sequence.

should be established.

 

 

 

 

 

 

Pg. 4

Image 4
Contents KEY Symbol Press Bell Symbol Press Talk first, then Bell buttonVolume Controls Names & FunctionsWiring Diagram Surface Mount InstallationFlush Mount Installation Terminal LocationsProgramming & Operation Press END button on GFO-1DL after it has been programmedTroubleshooting Guide OperationFCC Class B Verification SpecificationsToll Free Technical Support

GFO-1DL, GFO-1DLF specifications

The Aiphone GFO-1DLF and GFO-1DL intercom systems represent cutting-edge advancements in communication technology, designed to enhance safety and convenience in various environments. These models are part of Aiphone's commitment to delivering reliable and efficient intercom solutions, suitable for residential, commercial, and institutional applications.

One of the defining features of the GFO-1DLF and GFO-1DL is their high-quality audio and video capabilities. Equipped with a 7-inch color LCD monitor, these intercoms provide clear video images, allowing users to see who is at the door or entering a specific area. The resolution ensures that details are captured accurately, enhancing security and helping users make informed decisions.

Another key characteristic is the flexibility offered by these devices. The GFO-1DLF model includes a camera with a wide-angle lens, ensuring a broader field of view. This feature is particularly beneficial in monitoring entry points without requiring the user to manually adjust the camera. Additionally, the system supports two-way communication, making it easy for users to converse with visitors or staff without the need for physical presence.

Both intercom models utilize advanced digital technology, which significantly reduces interference and enhances audio clarity. The noise-canceling feature particularly stands out, as it minimizes background sounds, allowing users to focus on the conversation at hand. This adds to the overall user experience, making communication seamless and effective.

Moreover, the Aiphone GFO series stands out for its ease of installation and integration. The intercoms can be connected to existing wiring systems, simplifying the setup process. Wireless options are also available, providing users with more flexibility regarding their communication infrastructure. The systems are compatible with various Aiphone accessories, expanding their functionality and versatility.

Safety is paramount in any intercom system, and Aiphone has included features such as a locking mechanism for doors and gates, which can be controlled directly from the intercom unit. Users can grant access remotely, ensuring security without compromising convenience.

With these characteristics, the Aiphone GFO-1DLF and GFO-1DL intercoms offer a powerful combination of audio-visual clarity, user-friendly operation, and enhanced security features. As technology continues to evolve, these intercom systems reflect a commitment to innovation and efficiency, making them a wise choice for anyone looking to upgrade their communication capabilities.