RFID Electrical Considerations

RFID Electrical Considerations

Operating time

Under normal operating conditions, the RFID battery will last longer than the Falcon battery. Extended continuous operation may result in the RFID battery discharging before the Falcon battery. When using “paint” mode, the battery will last approximately 3 hours.

If the RFID unit fails to operate or produces error messages on the Falcon screen, it could be an indication that the RFID battery is becoming depleted. The red indicator light will begin to flash when the battery gets low. See LEDs/Indicators on page 6 for more information.

Charge time

You must charge the Falcon in the RFID-compatible dock prior to first use. The initial charge time is approximately 24 hours. See “Charging the Batteries” in the Falcon 4400 Series Quick Reference Guide (QRG) for more information.

CAUTION

After the initial charge, normal charge time is approximately 4 hours. The time depends on how much charge is in the battery when charging begins.

Addendum

5

Image 9
Contents Falcon 5500 Rfid PSC Inc Table of Contents Table of Contents Overview Falcon 5500 RfidGetting Started IntroductionEnabling Rfid Reading Rfid Tags Aiming the Falcon PaintingRfid Electrical Considerations Operating timeCharge time LEDs/Indicators Rfid Battery Charge LEDsDischarge indicator Falcon 5500 Dock Audio Configuration SettingsReport Settings Rfid SettingsRead Limits PowerFirmware Version Reading tagged items from an entire shelf Configuration ExamplesClass 1 Gen 2 Q value Rfid Antenna About Rfid TagsRead Range Proximity of TagsFactors Affecting Performance Tag OrientationMin Max Fac Tory Other Controls Configuration ParametersSets the Q value to be Used for reading Class Code Parameter/ Description Rfid Programming Labels TAG Read Beep Duration TAG Read Beep ToneMaximum Read Power Minimum Read PowerClass 1 Generation 2 Q Total Read Timeout NEW TAG Read Timeout Inifinite 100 150 200 250 Minimum TAG Read CountRead Report Frequency FCC Statement Safety InformationFCC Interference Statement FCC Radio Frequency Exposure statementSafety Information Falcon 5500 Rfid Mobile Hybrid Computer Addendum Safety Information Falcon 5500 Rfid Mobile Hybrid Computer Page Asia Pacific Italy